联系人 Ms. Jessie
5F Zhilianjia Building, No. 9002 Longxiang Road, Longgang District, Shenzhen, Guangdong
1. Static Demonstration Function:
Arrange the air conditioning system assembly and related components
in logical places so that trainees can easily understand the
structural composition and working principle of automatic air
conditioning.
2. Dynamic Operation functions:
(1)It can carry out the two major automatic refrigeration and
heating experiments for air conditioning.
(2)Be familiar with the functions of automatic air conditioning
through the training on controlling wind door, temperature, air
volume and air direction.
(3)Achieve the functions of automatic controlling air volume and
refrigerating capacity.
(4)Conduct refrigerating experiment by using motor driven
compressor to so that trainees can easily understand the working
principle of the self-adjustment of compressor with automatic air
conditioning variables.
(5)Through refrigerant recycling device, experiments on filling,
recovering, vacuumization and leakage inspection by pressure of
refrigerant can be carried out normally.
3. Real-time Display Functions:
(1)Pointer pressure gage display the pressure of high pressure
pipes and low pressure pipes by pointer pressure gage.
(2)Digital temperature gauge display the air temperature on air
outlet of evaporator.
4. Inspection Function:
Through connecting external detecting terminals directly on panel,
various parameter inspections can be conducted on computer related
terminals, sensors and transducers and actuators. The OBD-II
diagnostic interface for supporting the original automobile can
carry out data diagnosis and basic setting to the whole system by
using decoder.
5. Function for Data Parameter Adjustment:
It can carry out parameter adjustment on the major sensors and
transducers (including light sensor, outdoor temperature sensor,
indoor temperature sensor and pressure transducer etc) on automatic
air conditioning, and sense the change of air conditioning
operation status in real time result from the change of
signal of sensors and transducers.
6. Functions of Fault Setting and Examination:
The intelligentized system for fault setting and examination can
carry out fault simulation and clearing for related parts of air
conditioning system so as to simulate various fault conditions.
7. The visual air conditioning composition and principle diagram of
electronic control system fulfill the teaching demands of air
conditioning system composition and principle.
国家: | China |
型号: | C1147-PST |
离岸价格: | ( Negotiable ) 获取最新报价 |
位置: | - |
最小订单价格: | - |
最小订单: | - |
包装细节: | - |
交货时间: | - |
供应能力: | - |
付款方式: | - |
產品組 : | - |