China
联系人 zms
Zhengzhou, Henan
Application:This type of XLPE Insulated
Power Cable is used for power transmission and
distribution line with voltage rated at *5kV and below. In
comparison with PVC Insulated Power Cable, XLPE power
cable boasts not only characteristics of excellent
electricity, mechanism, heat and aging-resistant, environment
stress-resistant and chemical corrosion-resistant, but also simple
structure, light weight, no restriction by laying drop, and high
temperature allowance for long-term working.
0.6/1kV *-core XLPE Insulated Power Cable
0.6/1kV 4**-core XLPE Insulated Power Cable
*6/*5(*0.5)kV *-core XLPE Insulated, Steel tape Armored, PVC Sheath
Power Cable
XLPE Insulated Power Cable Standard:
1) Equivalent IEC ******1, GB/T****6.1;
Rated Voltage 1 kV (Um=1.2kV) and 3 kV (Um=3.6kV) Power Cable.
2) Equivalent IEC ******2, GB/T****6.2;
Rated Voltage 6 kV (Um=7.2kV) to *0 kV (Um=*6kV) Power
Cable.
3) Voltage Grade Overstep IEC****2, GB/T****6.3;
Rated Voltage *5 kV (Um=*0.5kV) Power Cable
Operating Features:
1)The maximum conductor
operating
temperature: *0℃;
During short circuit (lasting less than 5 seconds) the maximum
temperature of the cable conductor shall not be above **0℃;
Environment temperature should be no lower than 0℃ for laying the
cable.
2)Bending Radius of the
Cable:
Single Core Cable: Non Armored Cable *0D, Armored Cable
*5D;
Cores Cable: Non Armored Cable *5D, Armored Cable *2D.
Remarks: D means practical external diameter of
the cable.
Table**1, Type Description & Application Occasion of XLPE
Insulated Power Cable.
Description |
Application Occasion | GB China Type | |
Cu | Al | ||
XLPE Insulated PVC Sheath Power Cable | To be laid indoors,in tunnel,cable pipeline,the cable couldn't bear mechanical force outside. | YJV | YJLV |
XLPE Insulated PE Sheath Power Cable | YJY | YJLY | |
XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable | To be laid underground,able to bear a certain positive pressure. | YJV*2 | YJLV*2 |
XLPE Insulated,Steel Tape Armored,PE Sheathed Power Cable | YJV*3 | YJLV*3 | |
XLPE Insulated,Non-Magnetic Steel Tape Armored,PVC Sheathed Power Cable | YJV*2 | YJLV*2 | |
XLPE Insulated,Thin Steel Wire Armored,PVC Sheathed Power Cable | Apply to shafts,water and soil,able to bear the larger positive pressure. | YJV*2 | YJLV*2 |
XLPE Insulated,Non-Magnetic Thick Steel Wire Armored,PVC Sheathed Power Cable | YJV*2 | YJLV*2 | |
XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable | Apply to shafts,underwater and seabed,able to bear the positive pressure and the pull. | YJV*2 | YJLV*2 |
XLPE Insulated,Concentric Conductor,PVC Sheathed Power Cable | It is used for power transmission on power lines with voltage rated at 0.6/1 kV and below.It is widely used in petrochemical industry,metallurgy,mines and high-rise buildings,etc. | YJV-TP | YJLV-TP |
XLPE Insulated,Concentric Conductor Steel Tape Armored, PVC Sheathed Power Cable | YJV**-TP | YJLV**-TP | |
XLPE Insulated,Metallic Shielded,PVC Sheathed Power Cable | It is specially suitable for occasions with precision electronic devices,such as computer center,space & aviation supervision center,intellectual buildings,etc. | YJVP2 | YJLVP2 |
XLPE Insulated,Steel Tape Armored,Metallic Shielded,PVC Sheathed Power Cable | YJV*2P2 | YJLV*2P2 | |
XLPE Insulated,PVC Sheathed,Fire-Proof Power Cable | It is used for important occasions with high demand on fire-resistant performance,such as high-rise building,power station,power plant,mine,chemical industry,subway,etc. | NH-YJV | / |
XLPE Insulated,PVC Sheathed,Steel Tape Armored Fire-Proof Power Cable | NH-YJV*2 | / | |
XLPE Insulated,PVC Sheathed,Fire-Proof Control Cable | NH-KYJV | / | |
XLPE Insulated,PVC Sheathed,Steel Tape Armored Fire-Proof Control Cable | NH-KYJV*2 | / |
Nominal Cross Section(mm²) |
0.5 | 0.*5 | 1 | 1.5 | 2.5 | 4 | 6 | *0 | |
Cu (Ω/km) | Non Tinned | *6 | *4.5 | *8.1 | *2.1 | 7.*1 | 4.*1 | 3.*8 | 1.*3 |
Tinned | *6.7 | *4.8 | *8.2 | *2.2 | 7.*6 | 4.7 | 3.*1 | 1.*4 | |
Al (Ω/km) | / | / | / | *8.1 | *2.1 | 7.*1 | 4.*1 | 3.*8 | |
Nominal Cross Section(mm²) | *6 | *5 | *5 | *0 | *0 | *5 | **0 | **0 | |
Cu (Ω/km) | Non Tinned | 1.*5 | 0.**7 | 0.**4 | 0.**7 | 0.**8 | 0.**3 | 0.**3 | 0.**4 |
Tinned | 1.*6 | 0.**4 | 0.**9 | 0.**1 | 0.*7 | 0.**5 | 0.**4 | 0.**6 | |
Al (Ω/km) | 1.*1 | 1.2 | 0.**8 | 0.**1 | 0.**3 | 0.*2 | 0.**3 | 0.**6 | |
Nominal Cross Section(mm²) | **5 | **0 | **0 | **0 | **0 | **0 | **0 | ***0 | |
Cu (Ω/km) | Non Tinned | 0.***1 | 0.***4 | 0.***1 | 0.**7 | 0.***6 | 0.***3 | 0.***1 | 0.***6 |
Tinned | 0.1 | 0.***2 | 0.***7 | 0.***5 | 0.***9 | 0.***6 | 0.***4 | 0.***7 | |
Al (Ω/km) | 0.**4 | 0.**5 | 0.1 | 0.***8 | 0.***5 | 0.***9 | 0.***7 | 0.***1 |
Rated Voltage (kV) |
3.6/6 | 6.0/6.0 | 8.7/*0 | *2.0/*0 | *8/*0 | *1/*5 | *6/*5 |
6.0/*0 | 8.7/*5 | ||||||
Test Voltage (kV) | 6.*3 | *0.*8 | *5.*5 | *0.*6 | *1.*4 | *6.*3 | *4.*8 |
Max.Discharge Capacity (pC) | *0 | *0 | *0 | *0 | *0 | *0 | *0 |
Rated Voltage (kV) |
0.6/1 | 1.8/3 | 3.6/6 | 6.0/6 | 8.7/*0 | *2.0/*0 | *8/*0 | *1/*5 | *6/*5 |
3.6/*0 | 6.0/*0 | 8.7/*5 | |||||||
Test Voltage (kV) | 3.5 | 6.5 | *2.5 | *1 | *0.5 | *2 | *3 | *3.5 | *1 |
Test Time (min) | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
国家: | China |
型号: | - |
离岸价格: | 0.1 ~ 20 / Meter 获取最新报价 |
位置: | - |
最小订单价格: | 0.1 per Meter |
最小订单: | 100 Meter |
包装细节: | Wooden Drum or As Your Request |
交货时间: | - |
供应能力: | 30000 Meter per Day |
付款方式: | T/T, L/C |
產品組 : | cable |