看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Z4 DC Machines

Z4 DC Machines

离岸价格

获取最新报价

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

-

包装细节:

-

交货时间:

-

供应能力:

-

付款方式:

-

现在联系
免费会员

联系人 Mr. minjun

Suite 401, 5 Hutai Road, Shanghai, Shanghai

现在联系

详情

Features: 1) Technical standards: A) Continuous duty: S1 B) Domestic environmental standard: GB/T **5 (fundamental technical qualifications for motors) 2) Specifications: A) Nominal rated voltage: **0V, **0V (**0V, **0V or other voltage available) B) Nominal field voltage: **0V C) Rated speed (nine grades): **0r/min, **0r/min, **0r/min, **0r/min, **0r/min, **0r/min, ***0r/min, ***0r/min, ***0r/min 3) Operating ambients: A) Altitude: Less than or equal to 1, **0m B) Maximum cooling temperature: *0oC C) Free from acidic, alkali fumes or other irritant gas which could corrode insulating materials 4) Compensation windings available for Z****5, Z****5, Z****0 and Z****0 5) Z****0 and Z****0 are also feasible with compensation windings 6) Marked earthing terminals supplied Armature and field circuits for motors may be either operated by static thyristor controlled supplies or DC generators. Torque can be maintained constant by reducing speed via weakening armature voltage below rated value. We assure that the lowest armature speed range can be decreased to *0r/min by invariable torque and stable running. Meanwhile, field voltage is reduced to weaken speed with a steady output. These motors have separate excitations. In addition to the above listed nominal field voltage, other kinds of excitation voltage are also acceptable according to customers&#**9; requirements. If voltage is less than **0V, forced excitation is allowed. When a motor is normally operating, the excitation current should be no higher than the rated excitation current. To keep the insulating materials of the excitation system reliable, the motor must be protected against self-induced voltage by a resistor connected in parallel with the field windings when the excitation circuits of the motor are interrupted. At rated field voltage, the resistance value of a shunt resistor is about seven times more than field resistance at low temperature. While the field voltage is higher than

Send a direct inquiry to this supplier

至:

Mr. minjun < Shanghai Modern Electric Co., Ltd. >

我想知道: