离岸价格
获取最新报价( Negotiable )
|Minimum Order
位置:
Baoding,Hebei,China
最小订单价格:
-
最小订单:
1 Set
包装细节:
Wooden box
交货时间:
45 days
供应能力:
40 Set per Month
付款方式:
T/T, L/C
联系人 Yolanda
No.5699,North 2nd ring road, Baoding, Hebei
1. About us:
Baoding TIanwei Hengtong Electric company is a domestic professional manufacture of power system neutral earthing equipments and complete implements ISO***1 quality management system. We have a excellent sales performance all over the world and have been exported to more than *0 countries.
2. Principles:
THT-ZT Neutral Grounding Resistors are designed to provide added
safety to industrial distribution systems by limiting ground fault
current to reasonable levels. In a typical solidly grounded three
phase system, the neutral is tied directly to earth ground. This
can cause high ground fault current (typically *0,**0 to *0,**0
amps) and excessive damage to transformers, generators, motors,
wiring, and associated equipment. Inserting an THT-ZT Neutral
Grounding Resistor between neutral and ground limits fault current
to a safe level (typically *5 to **0 amps) while still allowing
sufficient current flow to operate fault clearing relays.
3. Service conditions:
3.1 Ambient temperature: **0°C~*0°C
3.2 Altitude: less than ***0m
3.3 Relative humidity: less than *5% (*5°C)
3.4 Rated frequency: *0/*0HZ
3.5 Location: outdoor/indoor
4. Characteristics:
4.1Designed in strict accordance with IEEE Standard *2
4.2High efficiency of electric conductivity and high-temperature endurance nichrome resistor
4.3Corrosion resistant aluminized zinc steel,stainless steel,cold-roll steel enclosures.
4.4Corrosion resistant stainless steel A***0 screws
4.4 LZZBJ9 resin casting insulation enhanced type current transformer
4.5 Hidden binding structure Air-cooling system
4.6 Sealed cubicle with highest protection level of IP*5.
4.7 Intellect controlled unit realize the unattended operation
4.8 Fully factory assembled - no field assembly required
4.9 A zigzag connecting grounding transformer is needed when the transformer windings adopt delta connection.
5. Regular Technical Particulars for reference
Type
Rated Voltage(KV)
Short Time Current(A)
Flow Time (S)
Resistance Value(ohm)
Outer Dimensions(mm)
THT-ZT*6/*4.*4
6
**0
*0
*4.*4
***0x***0x***0
THT-ZT*6/*7.*2
6
**0
*0
*7.*2
***0x***0x***0
THT-ZT*6/8.*6
6
**0
*0
8.*6
***0x***0x***0
THT-ZT*6/5.*7
6
**0
*0
5.*7
***0x***0x***0
THT-ZT**0/*4.*3
*0
**0
*0
*4.*3
***0x***0x***0
THT-ZT**0/9.*2
*0
**0
*0
9.*2
***0x***0x***0
THT-ZT**0/7.*2
*0
**0
*0
7.*2
***0x***0x***0
THT-ZT**0/5.*7
*0
***0
*0
5.*7
***0x***0x***0
THT-ZT**5/*0.*1
*5
***0
*0
*0.*1
***0x***0x***0
THT-ZT**5/*0.*0
*5
***0
*0
*0.*0
***0x***0x***0
Notes: manufactures various resistors according to the customer\'s requirement, the design inaccuracy is ±3%, the flow time is various from *0s, *5s,*0s, *0s,2h.
6. Information needed to quote:
6.1 System Voltage
6.2 Line-to-Neutral Voltage
6.3 Current Rating
6.4 Maximum Time On
6.5 Current Transformer Ratio, capacity (if applicable)
6.6 Grounding Transformer KVA Rating, connection symbol and the transformation ratio (if applicable)
6.7 Material of the enclosure:aluminized zinc steel,stainless steel or cold-roll steel
6.8 IP protectional grade
6.9 Color
6.*0 Installing place
6.*1 Line mode.