17-1616,No.5, Wei Hua Road, Suzhou Industrial Park, Suzhou, Jiangsu
现在联系
详情
Source and quality of raw
water water source : Middle East sea
water water quality :According to the
related material understanding, we by an average of seawater
contains a large number of colloidal material, salinity 36000ppm,
for reference in design for data. Temperature :15-25 ℃℃ 1.1
Water supply system:water supply
rate:200m3/h;temperature:15-25℃; ;Pressure:0.15-0.30.Mpa 1.2
Air supply system :clean,dry and oil-free compressed
air;pressure:0.7 Mpa 1.3Power supply
system:500KW,380V/50Hz/5Ф;220v/50Hz/1Ф 1.4
main technical parameters 1.4.1 ultrafiltration device feed water quality
requirements: Temperature: 5-40 ℃ PH:
3-11 Filtration system pressure:0.1-0.3
MPa System
design:Ultrafiltration system by ultrafiltration pump,
ultrafiltration membrane module, measurement instrument, cleaning
device, dosing device etc. Effluent is:Suspended solids removal rate: 99
percent after purification suspended 1mg/L acuities.Turbidity: more
than 0.2 NTU pollution index SDI < 3 Water production rate > 90% 1.4.2 seawater
reverse osmosis ingoing water quality requirements:Inlet water
temperature shoulds not be too low, such as <
10 ℃, feed need to
add heating Settings. The
highest design inlet water temperature is unfavorable exceed
40 ℃ System design: The
reverse osmosis device by the security filter, high-pressure pump,
reverse osmosis membrane module, flushing system, chemical cleaning
system, dosing system, measurement instrument and electrical control system etc. Effluent is:Of drinking water quality recovery:
40 percent 1.4.3 electrical
equipments Control cabinet: it contains PLC, rack
accessories, with current, voltage display, take leakage,lack of
such protection device Components: Siemens company or the same
brand Protective level: IP54 Material: carbon steel pensu 1.4.4automatic control
system Ultrafiltration system adopts PLC + industrial
computer automatic control method, realize full-automatic
operation, automatic reverse-wash process and to realize constantly
monitor filtering equipment, always detection function, including
circular trough level detection, clear liquid tank level detection,
rinse box level detection, cleaning box level detection,
ultrafiltration membrane equipment components import and export
pressure detecting, ultrafiltration membrane flux testing
equipment. Realize full-automatic integration, manual substation,
convenient operation.