离岸价格
获取最新报价300 ~ 600 / Set ( Negotiable )
|Minimum Order
位置:
-
最小订单价格:
最小订单:
1 Set
包装细节:
carton
交货时间:
3-5 days
供应能力:
200 Set per Day
付款方式:
Western Union, T/T
联系人 Mr. Stephen
guangzhou, Guangzhou, Guangdong
Parameter of vortex flow meter | |||||
Measured Mediums | liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.) | ||||
When the dryness of saturated steams ≥*5%, they can be seen as unidirectional. | |||||
Temperature of Mediums | - *0°C ~ + **0°C | ||||
Pressure of Mediums | 1.6MPa, 2.5MPa, 4.0 MPa | ||||
For over 4.0 MPa, please contact us freely, for it needs special customization. | |||||
Accuracy | 1.0; 1.5 | ||||
Span Rate | 1:8 ~ 1:*0(compared with the standard atmospheric pressure) | ||||
1:8 ~ 1:*0 ( compared with the nominal temperature water) | |||||
Flow Range | Liquids: 0.4 ~ 7.0 m/s | ||||
Gases: 4.0 ~ *0.0 m/s | |||||
Steams: 5.0 ~ *0.0 m/s | |||||
Nominal Diameter | DN *5, *0, *0, *5, *0, **0, **5, **0, **0, **0,**0 mm | ||||
Materials | 1Cr*8Ni9Ti | ||||
Reynolds No. | Normally, 2***4 ~ 7***6 | ||||
Resistance Coefficient | Cd ≤ 2.6 | ||||
Licensed Vibration Acceleration | LUGB type ≤ 0.2g | ||||
Class of Protection | IP*5 | ||||
Class of Explosion-Proof | Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 | ||||
Explosion Suppression: Exid II CT4 | |||||
Conditions of Surroundings | Temperature of Surroundings: | Non-Explosion Proof Surroundings: **0°C~ **5°C | |||
Explosion-Proof Surroundings: **0°C~ **5°C | |||||
Relative Humidity: | ≤ *5% | ||||
Atmospheric Pressure: | *6 ~ **6 kPa | ||||
Power Supply | Non-Explosion Proof Type | Pulse type: | **2 VDC ( the output current is 4 ~ *0mA) | ||
Current type: | **4 VDC ( the output current is 4~ *0mA) | ||||
Explosion-Proof Type | Current type: | **4 VDC ( the output current is 4~*0mA) | |||
Output Signal | Frequency pulse signal 2~***0Hz, low level voltage ≤1V, high level voltage ≥ 6V | ||||
Two-wire system 4 ~ *0mA signal (isolation output), load ≤ **0Ω. |
Measuring range of vortex flow meter MT**0VX
Measure range of vortex flow meter | ||
Diameter (mm) | Water | Gases in the Normal Temperature and Pressure |
Range of Standard Measurement (m3/h) | Range of Standard Measurement (m3/h) | |
*5 | 2 ~ *6 | 8~*0 |
*2 | 1.5~*5 | *4~**0 |
*0 | 3~*0 | *8~**0 |
*0 | 4~*0 | *0~**0 |
*5 | 6~*0 | *0~**0 |
*0 | *3~**0 | *0~**0 |
**0 | *0~**0 | **0~***0 |
**5 | *6~**0 | **0~***0 |
**0 | *0~**0 | **0~***0 |
**0 | **0~***0 | **0~***0 |
**0 | **0~***0 | **0~***0 |
**0 | **0~***0 | ***0~****0 |