Enginemates Heat Transfer has been involved in
working for a project in Morocco. Fin fan Cooler has been designed and fabricated
using the guidelines
from API **1 and ASME Section VIII Div 1. The MOC for tube
bundle assembly SS **4 L and for structure
carbon steel. Air cooled heat exchanger type is forced draft
exchanger.
Project Location :- Jorf Lasfer,
Morocco
Project Title :- Dap Plants **7 B &
C
Application :- Steam Vent
Condenser
DESIGN DATA:-
Operating Fluid :- Steam
Heat Load :- ***0.6KW
Fluid In/ Out :- **3/**0 º C
Design Pressure :- 5.5
KG/CM2(A)
Test Pressure:- 7.1KG/CM2(A)
Design temperature :- **0ºC
SCOPE:-
Thermal design HTRI 6.0
Mechanical design In-house
Structural design Staad Pro
V8i
Fin fan Cooler assembly components are as
follows.
Tube bundle assembly with removable cover type header
box.
Structure assembly with motor mtg., walk way, hand rail, ladder
etc.
Fan assembly
Plenum chamber conical
type
Electric motor
Drive (bearing block) assembly with pulley and
belt
Fan guard and other guards (for pulley and
motor).