看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
KYN61-40.5 Armored remove AC metal enclosed switchgear cabinet electrical switchgear

KYN61-40.5 Armored remove AC metal enclosed switchgear cabinet electrical switchgear

离岸价格

获取最新报价

( Negotiable )

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

1 Piece

包装细节:

wood, carton

交货时间:

30

供应能力:

100 Piece per Month

付款方式:

Other, PayPal, Money Gram, Western Union, L/C, T/T

现在联系
免费会员

联系人 Ms. Jennifer

xixiangtang, Nanning, Guangxi

现在联系

详情

~KYN****0.5 Armored remove AC metal enclosed switchgear cabinet electrical switchgear

Ⅰ.Overview

KYN****0.5 removable AC metal-clad switchgear applies to *0.5kV, 3 phase, AC and *0/*0Hz electrical power network for receiving and distributing power energy and also for control, monitor and protect ion. It is applicable in general power system and occasions with frequent operation. The product conforms to GB***6: 3~*5kV AC Metal Enclosed Switchgear, IEC****4 & GB/T****2: The common technical clauses of HV Switchgear and controlgear Standard, DL/T*******7: Order Technical term of Indoor AC HV Switchgear and IEC********0 1~*2kV AC Metal Enclosed Switchgear and controlgear standard. 

Ⅱ.Environmental conditions 

1) Suitable Temperature: **0℃ ~ **0℃, Daily average temperature:≤*5℃. 

2) Suitable Altitude: ≤***0m 

3) Relative Humidity: Daily mean ≤*5%, monthly mean ≤*0% 

4) Gradation of Earthquake Damage: ≤ Level 8

5)Daily average of 5. shall not exceed 2.2Kpa, monthly average shall not exceed 1.8kpa;

6)Places without fire, explosion hazard, serious pollution, chemical corrosion and violent vibration.

Special working conditions: for use when exceeding the specified normal environmental conditions, the user and the manufacturer shall negotiate.

Ⅲ.Specification

No. Items Unit  Parameters

1 Rated voltage KV *0.5

2 Rated frequency Hz *0(*0)

3 The main busbar rated current A ***0,***0,***0

4 Branch busbar rated current A **0/***0/ ***0

5 Rated insulation level Power frequency withstand voltage in 1min  (Effective value) Phase-phase,

Phase-ground KV *5

   Primary isolation fracture KV **5

   Lightning Impulse Withstand Voltage

(peak value) Phase-phase,

Phase-ground KV **5

   Primary isolation fracture KV **5

  Power frequency withstand voltage of auxiliary control circuit   V ***0

6 Rated short circuit breaking current KA *5/*1.5/*0

7 Rated short circuit closing current (peak value) KA *3/*0

8 Rated short-time withstand current (4S) KA *5/*1.5/*0

9  Rated peak withstand current KA *3/*0

*0 Rated voltage for split and auxiliary circuits: V DC *4,*6,*8,*0,**0,**0, AC **0,**0V

*1 Protection grade   Enclosure IP4X, IP2X,IP3X When the door of the circuit breaker opens

*2 Outline size (width * depth * height) mm ***0(***0)****0(***0)****0(*includes an internal digital SF6 handcart scheme)

*3 weight kg ~***0

Structure Description: 

Switchgear according G****6 and IEC**8 standards and design,And can be removed from the cabinet as a whole unit (trolley )components .

Cabinet structure are made of aluminum deposited zine plate or galvanized sheet assembled with both connection ,separate circuit breaker switchgear roon ,bus room ,cable room and instrument room,All metal components are grounded ,each compartment of the main circuit .system have separate pressure release channel in the cable compartment can be set *0**0mm ground bus .

Ⅵ.Features

1.The use of assembled cabinet structure ,circuit breaker handcart floorstanding structure ,Samall size:

2.Optional: The company vacuum breaker VW***0.5,xiamen huadian vacumm breaker VEP**0.5 ,similar circuit breaker are interchangeable .

3.Equipped with special transport vehicles can lift ,transport vehicles cabinet accurate positioning ,locking and reliable 

4.The main switch ,handcart ,door interlock switch between mandatory mechanical locking methods are used to meet the\'Five Anti\' interlock function .

5.all operation can be carried out at the door closed state ,to protect the safety of the operator .

6.Cable ample room space ,can be connected to multiple cables ,and overhead outlet .

7.Shell protection grade IP3X,handcart room door open between the various compartments protection class IP2X.

8.The material can be galvanized sheet can be deposited alumimum zinc plate production .

Send a direct inquiry to this supplier

至:

Ms. Jennifer < Guangxi Ayump Electric Power Technology Co., Ltd >

我想知道: