联系人 Mr. frank
Shenzhen, Guangdong
AC60 General Purpose Inverter( G/P mode)
A dual mode design with optimized V/f control , bring you high performance control with large starting torque and high speed accuracy control.The inverter is especially characterized by its customer-oriented performance and ease-use. Its large mains voltage range enables it to be used all over the world with cost-efficiency.
Specification
1 PH AC 220V±15%, 0.4 to
2.2kw
3 PH AC 220V±15%, 0.75 to
90kw
3 PH AC 380V/660V±15%, 0.75 to
1000kw
3 PH AC 1140V±15%, 30 to
1000kw
AC60 series excellent control characteristic
Outstanding V/f Control Mode Provide As good As Vector
Control Performance.
1.Lower noise and lower harmonic output extend motor lifetime
2.Adjusting carrier frequency according to temperature of Power
module to meet application automatically.
3.Lowest carrier frequency PWM technology help to reduce the
leakage current. Motor control distance longer is available.
4.Flexible V/f control pattern
5.Powerful auto torque boost ability, provide large torque
output.
Strong Environment Adaptability
1.Wide power range , improve the overload capacity via PWM
technology during low voltage . The protection ability such
as power surges protection, Thunder prevention, grid noise,
electrostatic anti-interference to meet highest industrial class
standard.
2.Surface mount technology and Protective PCB coating. Provide
higher protection for needing serve in application which full of
dust and moisture.
3.Apply independent air duct design through all power range,
especial designed to use in harsh environment with sealing
construction for medium and large power range.
Momentary Power Loss Ride-Through Function
It puts the drive in standby mode during transient power losses
and then automatically restarts with speed search function using
regenerative energy from motor.
Rich and multiple function to meet various industrial
applications
wobbling Function: especial using in textile, chemical
application which required waving frequency control. User setting
automatically for amplitude, speed and frequency parameters.
Multiple Communication Function.
Integrated international standard Modbuscommunication protocol.
User can achieve remote control via PC/PLC, such as inverter
control command, running frequency relative function code
modification, inverter running status and alarm monitor.
1. Standard Modbuscommunication is available for all range.
2. Built in RS485 communication card through 11G.
3. Profibuscommunication card is optional.
Simple PLC, up to 15 channel multiple speed is available
Rich I/O Terminal
Function
• 8 Digital Inputs, ( forward, reverse and 6 programmable digital
terminal. )
• 3 Analog Inputs. VS1, VS2 (0-10V, -10V to 10V), AS ( 0/4 to
20mA)
•1 Pulse Inputs.
• 3 Digital Outputs.( 2OptoCoupler and 1 relay )
• 2 Analog Outputs ( 0-10V, 0/4-20mA )
• 1 Pulse Outputs
• RS485 ModbusRTU Communication.
DC Bus Common
Technology
More energy saving, more green environment, cost saving
Applicable of AC60 Application:
AC60 G type are suitable for general load such as Conveyor Grinding machine, Centrifuges, Mixers, Industrial laundry, Automatic assembly, Packing equipment, Material handling, Food processing, Injection molding machine, Wood working machine, HAVC, Extruder, drawing machine in wind and unwind… AC60P type are suitable for variable load, such as pumps, fans, blowersAC60 developed by 2006, and put into market in 2007. Veichihave grown quickly thanks to this great sword product with high performance and reliable running quality.
Specificaiton:
|
Items |
Specifications |
|
|
Power |
Voltage,frequency |
Single phase 220V 50/60Hz Three phase 220V 50/60Hz Three phase380V 50/60Hz Three phase660V 50/60Hz Three phase 1140V 50/60Hz |
|
Allowable fluctuations |
voltage:±15%, frequency:±5% |
|
|
Control |
Frequency control range |
G:0-400Hz P:0-400Hz Z:0-400Hz, L:0-400Hz H:0-2000Hz |
|
Output frequency accuracy |
±0.5% of max frequency |
|
|
Frequency setting resolution |
0.01Hz:digital 0.2Hz:Potentiometers analog |
|
|
Voltage/frequency characteristics |
Voltage 50% -100% the rated voltage adjustable, Motor rated frequency 25-400Hz(2000Hz) adjustable |
|
|
Carrier frequency |
1.0-15.0KHz,Random carrier modulation |
|
|
Torque boost |
0~25.0% adjustable,auto torque boost,random V/F curve optional |
|
|
Overload capacity |
G,H,L model:150% for one minute, 180% for 2s, 200% instant jump. Z model:150% for one minute, 180% for 30s ,250% instant jump. P model:120% for one minute, 150% instant jump. |
|
|
Acceleration and Deceleration time |
0.1-6500s |
|
|
Rated output voltage |
Take advantage of the power supply voltage compensation function, the voltage can be set in the 50 -100% scope but not exceed the voltage.( rated voltage defined to 100%). |
|
|
Automatic voltage adjustment function |
Keep output voltage stable when the grid voltage fluctuates, |
|
|
Automatic energy-saving operation |
According to the load conditions, automatic optimize the V / F curves to implement energy saving operation |
|
|
Standard functions |
PID control, Acceleration and deceleration time adjustable, Acceleration and deceleration mode variable, Carrier frequency adjustment, Torque upgrade, Current limiting, Speed tracking and restart, Frequency hopping, Frequency fluctuation limiter control, Program running, Multi-steps speed, Pendulum frequency operation, RS485, Analog output, Pulse output frequency |
|
|
Brake |
Energy-consuming braking, DC braking |
|
|
Frequency setting |
Keyboard number settings, keyboard potentiometers, external terminal VS1 : 0 ~ 10V, external terminal VS2: - 10V - 10V, the external terminal AS : 4-20mA, RS485 and signal composition and terminal options |
|
|
Signal feedback |
External terminal VS1 : 0 ~ 10V, external terminals VS2:-10V - 10V, external terminal AS : 4-20mA, RS485, frequency pulse |
|
|
Input order signals |
Start, stop, positive and negative rotating , jog, multi-steps speed, free parking, reset, acceleration and deceleration time choice, frequency settings channels choice, external malfunctions alarm |
|
|
External output signal |
Relay output, the collector output, 0-10V output, 4-20mA output, the frequency pulse output |
|
|
Protection function |
Overvoltage, undervoltage, current limiting, over-current, overload, electric thermal relays, overheat,pressure stall, data protection |
|
|
Display |
Setting |
Function number,data |
|
Running |
Output frequency, give frequency, output current, voltage, output voltage, motor speed, PID feedback, quantitative PID, module temperature, and output terminal |
|
|
Fault |
Overvoltage, under voltage, over current, short circuit, phase missing, overload, heat, pressure stall, current limiting, data protection is damaged, current fault operating conditions, historical fault |
|
|
Condition |
Installation sites |
Indoor, altitude more than 1000 m, no corrosive gases and direct sunlight |
|
Temperature, humidity |
-10—+40°C, 20%—90%RH(No condensation) |
|
|
Vibration |
Below 20Hz less than 0.5g |
|
|
Storage Temperature |
-25—+65°C |
|
|
Installation mode |
Wall-mounted mode, closet mode |
|
|
Protection degree |
IP20 |
|
|
Cooling Mode |
Forced air-cooling |
|
Rated current and size
Installation size

Parnter and Customer
| 国家: | China |
| 型号: | aC60 general purpose inverter |
| 离岸价格: | 65 ~ 10000 / Set 获取最新报价 |
| 位置: | - |
| 最小订单价格: | 65 per Set |
| 最小订单: | 1 Set |
| 包装细节: | carton packaging |
| 交货时间: | 1-2 days |
| 供应能力: | 1000 Set per Day |
| 付款方式: | - |
| 產品組 : | - |