Installation: first, fix the cover, then hang the lamp to the
lifting hook on the ceiling, at last, connect
the AC power(please note the fire line and the zero line).
Maintaining introduction:
Before operating, please confirm the electricity is
disconnected.
Regularly clean the lens, keeping the lamp with good light
transmission.
Regularly clear the housing, keeping the lamp with good heat
dissipation.
Avoid using water or strong corrosion liquid to do the cleaning.
Better to use the dry dishcloth
When need to change the driver, firstly open the cover on the back
of the housing with a screw driver, then replace the old
driver with a new one.
Attentions here: how to connect the wire:
On the AC side:
The Red line connect to the "L" on the driver, and the Blue line
connect to the "N", the yellow green line or yellow line connect to
the ground wire**-
On the DC side:
The Red line connect to the positive pole, the black line connect
to the negative pole.
Please note that do not connect it wrong, otherwise, the driver
will explode or not work.