离岸价格
获取最新报价2475 ~ 2800 / Set
|1 Set Minimum Order
国家:
China
型号:
QD
离岸价格:
2475 ~ 2800 / Set 获取最新报价
位置:
-
最小订单价格:
2475 per Set
最小订单:
1 Set
包装细节:
Wooden Box
交货时间:
1-7 work days
供应能力:
600 Set per Month
付款方式:
T/T, Western Union, Money Gram
產品組 :
联系人 Ms. Connie
Longhua, Shenzhen, Guangdong
Features:
(1) New analog circuits and digital circuits combined , greatly improving the reliability and intelligence .
(2) Using the new *-inch touch screen and LSI components. The analog signal from the CPU to complete collected and converted to digital for processing and output. Automatic search of the detected metal content matter optimum point , greatly improving the detection sensitivity and reliability.
(3) Use of human interface design. The operation simple and intuitive. HMI glance. All functions operate directly on the screen to complete the perform.
(4) You can set all the necessary functions and modes , and diagnostic functions. Sensitivity: sub-stall , adjustable increase, decrease ( **9 stalls adjustable ) , digital large lower sensitivity . Detect trace metals , the sound and light alarm simultaneously , substandard products automatically return to the stop status and exclusion device control separation .
Ⅰ, Instructions:
The machine power switch in the rack power supply box to the right , press to open up , press
down to Off. After power indicator light. Put into the main menu.
There are six main menu functions to achieve the machine to complete all of the features , were given the following description:
1 : Parameter settings
Parameter settings have sensitivity settings , select the operating mode .
A, standard operating mode is fixed sensitivity , which is determined at the factory reference signal sensitivity and sensitivity is fixed at 9 , is not modifiable values, select the standard two words when you can just click , the corresponding box is selected for the white .
B, Custom work: Click Customize, corresponding to the white box is selected. Then the user can capture the results of the product tested to automatically set the sensitivity reference level . See Chapter capture operation . After setting parameters press the return key to save the data . Sensitivity setting of *0 , 1 being the highest sensitivity. 9 is the lowest , 0 is off.
2 : Time setting:
In the main menu, click Date and Time , enter the date and time setting interface
.
Click the accurate date when the value can be modified using + - number to increment or decrement , modify the finished press the Save to save , press the Back key to return to the previous menu.
3 : Detection method:
In the main menu, click detection methods , into the detection mode setting interface
.
Detection method for the three alternative ways to select a certain way can directly click on character blocks , white is selected
(1). automatic alarm signal is detected , the conveyor stop, continue to move forward and outputs flap signal ( when used with the flap ) , and flap signals move long duration can be set separately , setting method, see feature set .
(2). manually after the alarm signal is detected immediately shut down , such as the start again press the start to continue.
(3). rewind mode is detected, the alarm signal, the conveyor belt moving in the opposite direction , moving distance and a stop time can be set , setting method, see function setting.
4 : feature set :
In the main menu click feature set, enter the function setting interface
.
4.1 flap settings, which corresponds to the detection method in the automatic mode the parameters involved in the content , which is to go with time alarm signal is detected , substandard goods were seized from the probe to exclude the distance between the devices go with time , turn board time is the exclusion devices solenoid pull time .
4.2 rewind setting , which corresponds to the rewind mode detection method involved in the parameter content, rewind time the alarm signal is detected , the probe was detected defective position back to the return conveyor entrance time , this time for the operator to stop the unqualified products take time .
4.3 : Red peripherals Built-in, this function is put heavy items on the conveyor belt to vibrate when interference increases settings. ( This feature is not fitted infrared probe should be set to off )
Walking with time and position of the probe to the infrared objects are moving in time , the delay time of the seized goods to the probe infrared distance away time .
4.4: other settings , this setting has two settings, ( a ) voice prompts, click on the screen when turned on there will be voice prompts. ( 2 ) screen saver , when the screen is turned off when no operation will close five minutes .
4.5: Language settings , this feature is available for both Chinese and English language operation, click a language and press Save and then return to the previous menu.
4.6: return to the menu , click to return to the previous menu .
5 : Test substance :
In the main menu, click the test substance into the test substance screen.
It is in the custom mode, this function is used to collect the material effects of the measured product. With the measured results to automatically set the reference level of the machine. When you run the test in order to compare the level higher than this value will alarm.
To do the following, press the capture Jian, rotating machine, the machine does not make detection of the first three seconds, three seconds after the machine into the material effects of information capture products, then put the product into the conveyor detected in the collection, until the machine stops automatically as acquisition is completed. A minute later the conveyor is stopped, this time the results are displayed as a numerical effect of the collected material products, in order for the test results to the reference point. Select the bottom of the "+ - Kin to different products can be collected and stored separately, you can save a total of nine products information material effect。
6: Detection run:
In the main menu, click Run into the detector detects run the page as shown below.
In the detection of the page, click Start to run the machine began to turn healthy, no detection of the first three seconds, three seconds after detection of objects to be placed, when products containing metals alarms (based on testing methods set) stop or rewind or product automatically removed. On this page can also be sensitivity settings, select FE or SUS point "+ -" to increase or decrease the sensitivity, the sensitivity of this setting after shutdown does not save this setting.
II: Installation and Maintenance:
1 To prevent accidental electrical shock, do not put debris placed on the equipment, especially electrical connection can not be placed at the.
2 The use of machinery equipment part **0V/*0Hz power supply, make sure the power supply voltage is correct.
3 In order to prevent accidents, connect the power supply circuit breaker at the machine, in order to promptly cut off the power.
4 there is flooding in the workplace, the power cord must be connected to an earth leakage circuit breaker.
5 grounding requirements are as follows: copper wire with a diameter of not less than 1.6mm in the ground. Ground resistance must be less than **0 ohm.
6 must be adjusted base adjustment screw to adjust the device steady.
7 should not be near large metal movement, such as mobile carts, metal doors.
8 should not be near the motor or inverter power equipment.
9 shall not be installed in the ground vibration.
Ⅲ, Installation Procedure
1. Carefully unpack the equipment placed in the designated qualified installation site.
2. Adjust the base adjustment screw to adjust the device to stabilize, there can not shake
3. Check the screws on the device, whether because of transportation cause loose.
4. Connect the power cord, note the power cord reliable and correct. Power cord connection is recommended to install a circuit breaker to protect the equipment accident moments.
5. Remove all foreign objects around the probe, power, tap the start , the test machine running observe motor rotation is correct.
Ⅳ, Mechanical transmission parts commissioning
1. Power connection open.
2. Place the unit running, set the sensitivity of the closed state is (0).
3. Tap Start by health, motor rotation, observe five minutes, the motor runs smoothly, whether there is a conveyor belt deviation, if there is deviation conveyor belts, conveyor belts, if there is deviation, adjust the output of the two conveyor hex bolts (clockwise rotation belt tight, counterclockwise rotation belts loose. belts tend to side when adjusting the side of tight spots, or the other side of pine point) until the transfer is running smoothly.
4. Pat conveyors, conveyor observed loose, tight is appropriate, whether the conveyor belt and the bottom of the probe friction. If the large loose or big tight regulation also makes two conveyor belt conveyor belt tension adjustment screw to moderate.
Ⅴ, simple troubleshooting
1, the conveyor belt deviation
1) to determine the suitability of the belt tension, if a large conveyor belt loose, easy deviation.
2) transferred to the pallet holder, near the outlet end of the conveyor belt has two adjusting screws, the belt tension can be adjusted by the two bolts.
3) observation is consistent tension on both sides, both sides of tension if not, will lead to a conveyor belt deviation.
4) through the two sides of the tension adjustment bolts and more consistent regulation can solve the problem of the conveyor belt deviation.
2, instrument is not sensitive
1) Check the probe hole if there is a large metallic foreign body, such as coins, keys, screws, etc.. Exclude metal impurities.
2) The product selection is correct.
3) if the detection sensitivity is adjusted to a minimum or if the data collected is too high. When data collection is too high, that this reference voltage and relatively high sensitivity will be reduced. Re-load the collection, if the data is high then turn off the switch at the motor speed controller, so that the motor stopped running for the collection, such as closing the acquisition, such as the motor in the normal range on a conveyor belt, said metal objects or rack bolts loose, to exclude foreign body and tighten the bolts can be solved. If you stop collecting data after the motor rotation may be high voltage detector is surrounded by high-power interference sources, such as vibration or power supply instability, then you can install power supply resolved. If not resolved, please call our Service Department.
4) When the machine is not installed infrared detector is selected open in the infrared. Close Infrared can be ruled out
5) If the above conditions are excluded, the detection sensitivity of the instrument still does not, please call our Technical Services Department.
3, Instrument periodically false alarms
1) conveyor is contaminated by metal impurities, if the conveyor belt by metal impurity contamination whenever contaminated sites through the detection zone, the detector will alarm, cleaning conveyor belts, excluding metal impurities.
2) Even if the product conveyor hold load testing, the instrument is still cyclical false alarms. At this time there may be around the detector power sources of interference, such as vibration sieve.
4, the motor does not start
1) Open the control box, "start" on the touch panel and the "stop" , observe whether the control module relay action, if any action, indicating that motor capacitor motor has been damaged or corrupted. You can buy the same model motor replaced, or contact the company service sectors. Non-professionals are not allowed to repair, to prevent electric shock hazard.
2) If the relay is no action, you can make the control module is damaged, or the cable is loose, remove the cable loosening, whether observed troubleshooting, if the motor still does not start, please contact the company service sectors. Non-professionals are not allowed to repair, to prevent improper repairs damage to other parts.
Switch 3 observed at the motor speed controller is in the off state. The case can be opened.
5, no electricity
Observe the power switch in the indicator light does not light, check the power outlet mounted fuse is blown, the power plug is loose, such as blown fuses please send randomly put on standby.
国家: | China |
型号: | QD |
离岸价格: | 2475 ~ 2800 / Set 获取最新报价 |
位置: | - |
最小订单价格: | 2475 per Set |
最小订单: | 1 Set |
包装细节: | Wooden Box |
交货时间: | 1-7 work days |
供应能力: | 600 Set per Month |
付款方式: | T/T, Western Union, Money Gram |
產品組 : | needle metal detector |