Uzbekistan
联系人 Mr. Botir
8-37, Yunusabad-10, Tashkent
POWER CABLES
Power cables
with plastic insulation in accordance with GOST
31996-2012 AVVG Power
cable with aluminum wire, PVC insulation and
sheath
VVG Power
cable with copper wire, PVC insulation and
sheath
AVBbSHv
Power cable with aluminum wire, insulation and
protective PVC hose, with armor of two steel
tapes
VBbSHb Power
cable with copper wire, insulation and protective PVC hose, with
armor of two steel tapes Area of
application The cables are intended for transmission and
distribution of electric energy in stationary equipment for nominal
voltage of 0.66 or 1 kV 50 Hz
Construction (Design)
Markings of wires | Description |
AVVG |
Conductor - aluminum wire Insulation - PVC compound, fireproof Sheath - PVC compound, fireproof |
VVG |
Conductor - copper wire Insulation - PVC compound, fireproof Sheath - PVC compound, fireproof |
AVBbSHv |
Conductor - aluminum wire Insulation - PVC compound, fireproof Armor - two galvanized steel tapes Hose - PVC compound, fireproof |
VBbSHb |
Conductor - copper wire Insulation - PVC compound, fireproof Armor - two galvanized steel tapes Hose - PVC compound, fireproof |
Names of specifications | Values |
Operating voltage kV | 0,66 or 1 |
Number of wires | from 1 to 5 |
Сross-section of main conductors, mm² | from 1,5 to 240 |
cross-section of neutral conductor, mm² | from 1,5 to 120 |
Class of conductors | 1 or 2 |
Length, m: When cross-section 1.5 to 16 mm² When cross-section 25 to 70 mm² When cross-section 95 to 240 mm² |
450 300 200 |
Operating Temperature, °C common industrial use ng - low flammability ng-LS with low gas emission and smoke when burning |
from -50 to +50 from -30 to +50 from -30 to +50 |
Insulation resistance, MOhm, not less for cross-section 1,5 mm² for cross-section from 2,5 to 6,0 mm² for cross-section 10 mm² and higher |
10 9 7 |
Minimum bending radius at laying, cable diameters | 20 |
Performance in terms of fire safety flame retardant in single laying flame retardant in group laying (ng): in categoryАF/R in category ng(А) in category ng(В) flame retardant while installing, with low smoke and gas emission |
ng(А F/R) ng(А) ng(В) ng(...)-LS |
Service life of the cable | Not less than 30 years |
Number of wires and cross-section, mm2 | The nominal outside diameter, mm | Design weight, kg/km | ||||||||||
VVG, AVVG | VBbSHb, AVBbSHv | VVG | AVVG | VBbSHb | AVBbSHv | |||||||
0,66 kV | 1 kV | 0,66 kV | 1 kV | 0,66kV | 1kV | 0,66kV | 1 kV | 0,66 kV | 1 kV | 0,66 kV | 1 kV | |
1*1,5 | 4,7 | 5,1 | - | - | 34,3 | 38,4 | - | - | - | - | - | - |
1*2,5 | 5 | 5,4 | - | - | 45,1 | 49,6 | 30,9 | 35,4 | - | - | - | - |
1*4 | 5,7 | 6,3 | - | - | 63,8 | 71,4 | 40,2 | 47,9 | - | - | - | - |
till 2*15 |
国家: | Uzbekistan |
型号: | 800231 |
离岸价格: | 1 ~ 5 / Meter 获取最新报价 |
位置: | Uzbekistan |
最小订单价格: | 1 per Meter |
最小订单: | 1000 Meter |
包装细节: | Rolls |
交货时间: | 25-30 days |
供应能力: | 50000 Meter per Day |
付款方式: | T/T, L/C |
產品組 : | CABLES |