Small chiller can be moved 2 tons BUSCH air-cooled box type
chiller
Model:BBP**3SA
Cooling capacity:8.8 kW / 2.5 RT
Whole unit power :3.1 kW
Whole unit current power:5.6 A
Compressor type:Fully enclosed scroll compressor
Compressor quantity:1 set
Condenser fan power :0.*9 kW
Condenser fan current power:0.5 A
Chilled water flow: *5L/min
Chilled water tube diameter:DN *5
Chilled water pump power:0.*7 kW
Chilled water pump lift head:*6 mH2O
Water Tank: *0L
Size:**0mm***0mm****0mm
Weight:**0 kg
Power standard:**0V/**5V/**0V/*3P**0Hz/*0Hz
Refrigerant:R*2/R**7C/R**4a
Non-standard product and design:Acceptable
BBP box-type of industrial water chiller
Box-type industrial chiller product technology features:
1.Principle and Use
Box-type industrial chillers are the units of which applicable
cooling(heating) medium is air or water in summer(winter), and
their secondary refrigerant is water. They are widely used in
various equipments and cooling models of plastics, electronics ,
food , pharmaceutical , electroplating , chemical , printing ,
coating , laser and CD-ROMs and other industrial.
2.Type
The box-type industrial chillers are equipped with chilled water
pump and water tank , which is easy to installed on-site and
maintain; box-type industrial chillers has two types, which are
air-cooled and water-cooled. These two type chillers can be the
selection of customers according to the situation. Air - cooled
conditions chillers do not need to be equipped with cooling water
system and can be installed outdoors easily, and it do not take up
too much space; water-cooled conditions chiller has a high
efficiency and a wider operating temperature range .
3.Evaporator
3 - 5HP chiller applies a submerged coil evaporator. More than 8HP
chiller applies a shell tube or plate evaporator with heat transfer
efficiency, and low water resistance .
4.Controller
All microcomputer controllers are accurate and intelligent. This
truly achieve perfect control of the machine in order to ensure the
safe operation of the units and achieve the purpose of effective
energy-saving , easy to use and friendly interface .
5.Water temperature & Antifreeze solution
Box-type industrial chillers can achieve water accessing in variety
of low temperature. After adding appropriate antifreeze in the
chilled water side, it can achieve 0C - *5C the water temperature
in order to adapt to different industrial cooling requirements;
Commonly used antifreeze solution can include ethylene alcohol,
sodium chloride and calcium chloride solution. It is proposed that
the application to set different concentration of antifreeze
solution for customers is based on water temperature. If you are
looking for freezing point of a variety of solutions, please refer
to the installation, use profile section.
6.Protection
Box-type industrial chillers have perfect protection function, such
as power wrong phase lack protection , System high-voltage
protection, System low voltage protection, Double antifreeze
protection, Compressor overload protection, The insufficient frozen
water cooling protection, Prevent frequent start protection,
Compressor built-in exhaust temperature, coil overheat temperature
protection and etc. These protections will reduce losses caused by
all kinds of accidents.
7.Customizing
Our company accept all kinds of special technical requirements of
units, which may include explosion-proof, strong acid, strong
alkali solution, cryogenic, heterogeneous power supply, T3
conditions and other non-standard products. Please contact with our
technology department before ordering.
8.Pump & Water tank
The standard accessories of box chillers can include stainless
steel water pump and water tank; Pump has a high lift , great flow
capacity and strong adaptability; the large capacity water tank can
automatically do replenishment or overflow, this effectively
barrier water temperature changes due to the load change, and also
stabilize the running cooling system.
9.Microcomputer function
Within the compressors of chillers, microcomputers are installed to
automatic memory operation time of each compressors. The
compressors with lower running time will be active first at next
time. This also applies to similar situation like discharging, The
compressors with longer operation time will be stopped first in
order to achieve the balance of each compressor operation to extend
the service life of the machine.
*0.Environment friendly protection refrigerants
At air cooled low temperature condition (below *0 C) , water
chiller units apply the Copeland of the low temperature and
environmental protection compressor R**4A refrigerants, which can
bring higher efficiency, longer running life, environmental
friendly and energy saving.
In order to better protect the atmosphere, it can produce green
environmental friendly cooling medium refrigeration and air
conditioning equipment not only in adopts HFC**7C and HFC**4a,but
also in HCFC*2.
*1.Movement
*- 8HP of the box-type industrial chiller`s bottom of the fuselage
is equipped with a wheel, you can easily move .
*2.Compressor & major refrigeration original
Compressor selection of Europe and the United States imports closed
scroll compressor (or piston) , small vibration, resistance to
liquid strike capability , high efficiency , wide operating
temperature range.
Every equipments except the compressor refrigeration components are
imported products, such as the expansion valve , solenoid valve ,
filter drier , European and American quality products , reliable
performance and precise control .
*3.Test center
The enterprise has a well-operated testing center , each
air-conditioning unit have been injected refrigerant and
refrigerant oil before leaving factory. After undergoing a rigorous
simulation of the standard conditions and maximum operating mode
detection, expansion valve can be adjusted to the best
condition.
Notes: (room temperature) default conditions
1.The parameters in the nominal conditions are as follows: chilled
water inlet / outlet water temperature is *2℃/ 7 ℃; Ambient
temperature is *5℃ .
2. Temperature conditions: Chilled water inlet temperature range 9℃
~ *0 ℃ ambient operating temperature 0 ° C ~ *3 ℃
3. Host the actual head of the pump head , minus the host internal
head loss ( 1mH2O = 9.8kPa )
4. Nominal conditions evaporation device water side of the dirt
coefficient is 0.**8 m ? ° C / kW
5. Power standard : 3P- **0V - *0HZ , it is recommended that the
three-phase system , allowing the voltage fluctuation of ± 5 % ,
the frequency fluctuations of ± 2%
国家: | China |
型号: | BBP-03SA |
离岸价格: | 3430 ~ 4500 / Set ( Negotiable ) 获取最新报价 |
位置: | - |
最小订单价格: | 3430 per Set |
最小订单: | 1 Set |
包装细节: | Plywood |
交货时间: | 18 days after order |
供应能力: | 10000 Set per Month |
付款方式: | T/T, L/C, Western Union |
產品組 : | BBP box package industrial chiller |