Features:
1. Automatic infusion: According to the doctors advice, set the
infusion volume and speed. The linear peristaltic pump which is
microcomputer controlled will manage infusion pump to make
automatic infusion according to the setting infusion speed.
2. KVO status: After finishing the total volume of infusion, the
pump will switch to KVO status automatically. (Keep vein open
status).
3. Audible and visual alarm: Five kinds of alarms including
Occlusion alarm, Bubble alarm, Door Open alarm, Infusion Finished
alarm and Under-voltage alarm. When infusion failed, audible and
visual alarm will occur and remind the operators to dispose in
time.
4. Apply to variety liquids: It can be used to infuse colorless
transparent liquid and high nutrient solutions and color opaque
liquid.
5. Apply to infusion apparatus:
Ordinary infusion apparatus: Normal PVC titration transparent or
lucifuge infusion apparatus (pipe diameter is about 3.5mm) can be
used. Please make sure the pipe diameter and pipe wall of infusion
apparatus must have a certain elasticity coefficient. New infusion
apparatus should take calibration of the infusion precision before
the first use. Note: Other specifications of the infusion apparatus
may not be able to maintain accuracy (Even if the precision is
being calibrated)
Specialized infusion apparatus: Specialized infusion apparatus has
high elastic silicone tube. Please contact our company for
purchasing.
Warning: The pump may be unable to maintain accuracy if use
infusion apparatus which is not recommended.
6. AC/DC alternative: Built-in NI-MH rechargeable battery makes
sure the device still can be used when the sudden power off. The
machine automatically charges itself when the battery volume is low
and stop when its fully charged, and the indication light switches
off. Please make sure its fully charged around 7hours or it will
shorten the lifespan of battery. Low voltage alarm will occur and
indication light will flash when the battery mostly runs out in
order to remind the operators to dispose in time.
7. Quick exhaust: Press the quick exhaust twice and enter
into quick exhaust status. The stop status is quick exhaust, and
the exhausted liquid will not be counted into cumulative infusion
rate. Start state is quick transfuse, discharged liquid will be
counted into cumulative infusion rate. Loosen the , the quick
exhaust state will be stopped.
8. Infusion rate: It has Drop/min and ml/h two setting modes for
users to choose. Note: Drop/min and ml/h is conversed from *0
Drops/ml, which is different from the actual drops.
9. Call interface: Reserve call interface to provide the
centralized monitoring function for nurse station.
Technical Specifications:
-Infusion flow rate:
Specialized infusion apparatus: 0.1ml/h****0ml/h;
Ordinary infusion apparatus: 0.1ml/h***0ml/h;
Remarks: with 0.***0ml/h (0.1ml/h/step); Over *0ml/h
(1ml/h/step).
-Infusion accuracy error:
Specialized infusion apparatus: ±5%(medium speed, *3℃,
humidity: *0%);
Ordinary infusion apparatus: ±*0%(medium speed, *3℃,
humidity: *0%).
-Total infusion volume preset: 0.*****9ml.
Remarks: with 0.***0ml (0.1ml/step); Over *0ml
(1ml/step).
-Occlusion sensitivity:
It has three adjustable levels of occlusion pressure:
Low speed (1ml/h): **0~**0 seconds;
Medium speed (**0ml/h): 7~*4 seconds;
High speed(**0ml/h): 0.2~1 seconds.
-KV O Rate: **2ml/h
-Built-in battery work time: 2 hours.