Built to ASME & AS***8
and China Boiler and Pressure Vessel Codes- "Safety
Technical and Supervisory Specification of Steam Boiler"(edition
*6), JB/T*********2 "General Technical Conditions of Industrial
Boiler", GB/T*********6 "Pressure Parts Strength Calculation of
Boiler Shell" and GB*********8 "Code of Construction and
Acceptance of Industrial Boiler"
Water Feed System
Strainer, solenoid valve and check valve factory wired and
plumbed
Low Water Cut-off/Level Control automatically maintains proper
water level, shutting off the boiler when water supply in the
boiler drops below a safe operating level.
Water Level Sight Glass allows constant observation of water
level while boiler is in operation.
Main On/Off Switch allows manual control of the boiler operating
control circuit
Pilot Light indicates control circuits on/off condition.
Integral Power Contactors
Magnetic contactors for energizing the boiler elements.
Integrally mounted in the control unit.
Blow down/Drain Valves facilitates emptying the boiler pressure
level
Energy Savings and Minimum Maintenance
Pressure vessel insulation minimizes heat loss and maximizes
energy savings, insured by fibrous glass material.
Operating Pressure Control resets automatically to maintain
preset pressure within boiler.
Easy Control Maintenance
All control panels and components are easily accessible.
Dry Steam
There is a steam and water separator built in the boiler with
efficiency over *8%. (Patent No. *****8)
2. SAFETY FEATURES
Real-time monitoring of water level: Electronic water-level
detecting device
Water shortage protection: The combustion control system power
will be cut off when there is water shortage along with
alarm.
Leakage protection: The power will be cut off when there is
leakage detected by the control system.
Over pressure protection: When the pressure is over the preset
value, the combustion control system power will be cut off along
with alarm.
Steam Safety Valve automatically opens to reduce pressure should
excessive steam cause pressure build-up.
Steam Pressure Gauge allows visual observation of steam pressure
over full range.
Manual Reset Pressure Control provides high limit pressure
cut-out with manual reset.
Complete gas manifolds and protection system for gas boiler:
Strainer, pressure regulating valve and magnetic valve
3. FACTORY ASSURANCE
*1 year parts warranty (on condition of using soft water)
-Size ranging from *0 to *5, **0 kg/h
-Different voltage available
-Stainless steel models available
-Skid-mounted boiler system available
-Wearing parts available at ex-factory price
Now have *0 units running in West brisbane
of Australia