联系人 Mr. William
12/F., San Toi Building,139 Connaught Road Central, Xiaolou, Guangdong
Product: Continuous Glucose
Monitor Meter CGM S1
High Light: Dynamic Glucose Monitoring System
help you build a blood glucose management paltform inside and
outside the hospital.
Prameter
Data Collection: Test Data every 11 seconds record
an average blood glucose level every 3 minutes
High and low blood sugar reminder: Can be set the
interval by yourself, and it will prompt if it is higher or lower
than the set interval.
Power Supply: Button Battery
Data Storage method: stored in the wireless
transmitter
Data Transmission Method: Bluetooth 4.0
Size: 44.2*28*12.5 mm
Valid range of Glucose concentration Test: 1.7
mmol/l-25mmol/l
Electrode Depth: 03mm±0.07mm
Effective Working Time: Not less than 120
hours
Accuracy:RE%≤12%
Wearing Part: Recommended to be worn on the upper
arm, and directly implanted under the skin without auxiliary
tools
Features
1.Real-time dynamic glucose
monitoring system high and low blood sugar
prompt.
Promote HbAIc compliance, without
increasing the risk of hypoglycemia. Correct in time to avoid
hypoglycemia.
Medical Evidence shows that blood sugar management under the
guidance of real-time CGM can achieve better blood sugar lowering
effects. And the decrease of glycosylated hemoglobin is positively
correlated with the frequency of use of glucose dynamic sensor.
That is, frequent real-time CGM, better blood sugar
control.
2.Dynamic blood glucose monitoring system
can visually display blood glucose fluctuations after
meals.
Help patients reduce the
percentage of high and low blood sugar time.
One value for 3 minutes,
accurately capture the peak blood glucose after a
meals
3. Miniature size high
sensitivity dynamic glucose sensor
Length is only 4 mm, Diameter 0.2
mm
The volume is only 1/4 of similar products, the contact area is
eight times that of similar products
The original free-hand implantation technology does not requie any
auxiliary equipment, and the whole wearing process is almost
paintless.
Integrated design of sensor and transmitter
4.Clinical accuracy of
dynamic glucose monitoring system
5.Application of pump
therapy.
6.Discovery of hypoglycemia that can not be captured
Unexplained severe
hypoglycemia
Asymptomatic hypoglycemia
Repeated Hypoglycemia
Nocturnal hypoglycemia
7.Found occult
hyperglycemia
High blood sugar fluctuations
Unexplained hyperglycemia
Fasting hyperglycemia
8.Discover the
indistinguishable dawn blood sugar
SMBG results are good, but HBA1c
is always not to standard
Out of fear of hypoglycemia, patients who deliberately maintain
hyperglycemia
Pictures
国家: | China |
型号: | S2 |
离岸价格: | ( Negotiable ) 获取最新报价 |
位置: | China |
最小订单价格: | - |
最小订单: | 3000 |
包装细节: | - |
交货时间: | 15 to 25 days, depends on final volume |
供应能力: | 50000 per Week |
付款方式: | T/T, PayPal |
產品組 : | Continuous Glucose Monitor System |