看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。
点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
SBL Target Mode Inserted Type High Temperature Compensation Flow Meter

SBL Target Mode Inserted Type High Temperature Compensation Flow Meter

离岸价格

获取最新报价

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

1set

包装细节:

-

交货时间:

-

供应能力:

8000/year

付款方式:

-

现在联系
免费会员

联系人 Mr. Congming

Rixin Mansion, No.2 Bridge, Nanhuan Road, Licheng District, Quanzhou, Fujian

现在联系

详情

Description (1) Description of flange Short connection flange shall execute relevant technical requirements in state standard GB/T***5.1~***5.*****0, or special standard such as American or European standard as required by user. (2) Description of structure a. For actual dimensions of high temperature or temperature/pressure compensation inserted type flowmeter, ex-factory (order) status shall govern. b. When media temperature of high temperature type flowmeter is >**0, the instrument must be installed up-side-down and horizontally. The design shall consider sufficient mounting space. c. If the media flow up-down or down-up, for ordering, please note: right view, left view (showing gauge head). Note: In this design, only fixed inserted type is provided; if telescopic online removable type is required, particular size shall be determined with manufacturer. Table of main technical indices Measured media Liquid, gas, steam Nominal diameter Pipeline type *5~**0mm Clamped mounting type *5~**0mm Inserted type **0~***0mm Nominal pressure 0.6~*2MPa 0.6~*2MPa 0.6~*2MPa Media temperature **0~*0 (normal temperature type) ***6~***0 (high/low temperature type) Accuracy ±0.2% ±0.5% ±1.0% ±1.5% ±2.5% Range degree 1:3 1:5 1:*0 1:*0 (gas) 1:*0 (steam) Compensation type Temperature compensation; pressure compensation Repeatability 0.1%~0.*8% Power supply Built-in 3.6V Li batter; external power supply of *4VDC; **0VAC (only for separate digital tube) Output forms Site display reading; 4~*0mA (*-wire system); pulse; 0~*0V; RS**2/RS**5 (optional) Material of measurement tube Carbon steel; **4; **6L; also supplied to user requirement Explosion-proof sign Intrinsically safe type (ExiallCT4); Explosion isolating type (ExiallBT4) Protection class IP*5; IP*7 Note: Size of flowmeter flange shall execute GB/T***5.1~***5.*****0 series standard. For pipelin

Send a direct inquiry to this supplier

至:

Mr. Congming < QUANZHOU RIXIN FLOW-METER AND INSTRUMENT CO., LTD >

我想知道: