看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Infant Incubator (B-2000)

Infant Incubator (B-2000)

离岸价格

获取最新报价

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

-

包装细节:

-

交货时间:

-

供应能力:

-

付款方式:

-

现在联系

联系人 Mr. Andrew

Rm. 1013, Luozi Pinge, Shiqi Street, Yinzhou District,Ningbo, Zhejiang 315153,China, Ningbo, Zhejiang

现在联系

详情

SPECIFICATIONS: Model: B****0 POWER Power Requirements: AC**0V *0%, *0Hz 2% Power Input: â¤**0VA Refer to IEC******1, this equipment belongs to Class I, Type B. Its operation is Continuous. ALARM Power Alarm Power Failure: Activates if primary power to the Incubator Fails or the power wire is accidentally Disconnected from the wall receptacle. Fan Alarm Fan Failure: Activates if Fan motor malfunctions. Sensor Alarm Air Sensor Failure: Air Sensor malfunction, refer unit to service. Sensor Out of Position: Activated when Sensor is not in correct position To perform calibration or continue operation. Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller. Skin Sensor Failure: Activated when Skin Sensor malfunctions. Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 1.5 centigrade above set point Low Air Temperature: Activated if displayed Air Temperature 2.5centigrade below set point Skin Temperature: Activated if displayed Skin Temperature is 1.0 centigrade above set point Low Skin Temperature: Activated if displayed Skin Temperature is 1.0Over Temperature Alarm Over Air Temperature: Activated when displayed Air TemperatureWas approach *8centigrade for set temperature â¤*7centigrade, Or approach *0centigrade for set temperature >*7centigrade in Air Mode. Over Skin Temperature: Activated when displayed Skin Temperature was approach *8centigrade for set temperature â¤*7centigrade, Or approach *9centigrade for set temperature >*7centigrade in Skin Mode. System Alarm System Failure: Activated if Temperature Control System malfunctions. TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS Air Temperature: *0centigrade ~*7centigrade, for set temperature â¤*7centigrade *7centigrade ~*9centigrade, for set temperature >*7centigrade Skin Temperature: *0centigrade ~*7centigrade, for set temperature â¤*7centigrade *7centigrade~*8centigrade, for set temperature >*7centigrade Temperature Rise Time: â¤*0min Temperature Variability: 0.5centigrade Temperature Uniformity: ⤠1 centigrade Skin Sensor Precision: â¤0.3centigrade ENVIRONMENT REQUIREMENT Environment Temperature Operation Temperature Range**0centigrade ~**0centigrade Store Temperature Range **0centigrade ~**0centigrade Environment Humidity Operation Humidity Range: *0%~*5% Store Humidity Range: â¤*0% Atmospheric Pressure Range: **0hPa~***0hPa OTHER SPECIFICATION Noise Level Within Hood Environment â¤*5dB(Environment noise below *5dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2 In air is delivered at **0ml/min At point *0cm above the center of the mattress. Air Velocit y Over Mattress less than: 0.*5m/s Infant Bed Max Load: *0kg Transfusion Shelf Max Load: 2kg Shelf Max Load: Cabinet Max Load: 6kg Infant Incubator (B-2000)

Send a direct inquiry to this supplier

至:

Mr. Andrew < China Shikang Medical Equipment Group Limited >

我想知道: