看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 立即加入 |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
JK-GAC-112A gasoline aromatics chromatography

JK-GAC-112A gasoline aromatics chromatography

离岸价格

获取最新报价

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

1

包装细节:

-

交货时间:

-

供应能力:

10

付款方式:

-

现在联系

联系人 Ms. Shelly

Room A304, No.189, Xinjunhuan Road, Minhang District, Shanghai, China, Shanghai, Shanghai

现在联系

详情

Characteristics: âEquipment performance standards: GBl********9 â Car to unleaded petrolâ , ASTMD********6 âmotor gasoline and aviation gasoline benzene and toluene content of the assay(GC)â Meet JB/T********2 "Laboratory of Gas Chromatography" , JJG*******0 "Gas Chromatography" âMicrocomputer temperature control system, high accuracy of temperature control (better than: ± 0.1 â) âControl and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time. âThree sets of steady carrier gas flow control. Accurate and scaled type gas path control valves will provide a high repeatability and stability. Directly read flow value and the adjustment is convenienceã âThermostat flat six-way valve provided with options of automaticly switching six-way valve components by computer timely. âAuto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling. âHigh separation efficiency, good repeatability. High sensitivity, low noise and the time is short of stable equilibrium of Thermal Conductivity Detector (TCD) âOpen-end computer system can apply RS***2 interface and FJ****0 chromatogram workstation to achieve dual path communication control and data processing. âLarge volume column (**0x**0x**0) can hold several dedicated packed columns. Can be used in multidimensional chromatography analysis Temperature control: âTemperature zones: column box, into the sample containers, thermal conductivity pool, six-way valve. âTemperature control range: 7â***9â of room temperature (increment by 1â) âTemperature accuracy: better than ± 0.1 â (**0 â). Thermal Conductivity Detector (TCD) âSensitivity: S> *****/mg (carrier gas: H2) âBaseline Noise: ⤠*0uV âBaseline drift: â¤*0uV/h JK-GAC-112A gasoline aromatics chromatography

Send a direct inquiry to this supplier

至:

Ms. Shelly < Shanghai Jingke Scientific Instrument Co., Ltd >

我想知道: