看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 立即加入 |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Pneumatic pressure calibration Pump

Sell Pneumatic pressure calibration Pump

离岸价格

获取最新报价

|

Minimum Order

位置:

Beijing

最小订单价格:

-

最小订单:

1

包装细节:

-

交货时间:

-

供应能力:

1000/WEEKS

付款方式:

-

现在联系
免费会员

联系人 Mr. Tony

Xinxi, Beijing, Beijing

现在联系

详情

The Model ConST**2 Pneumatic pressure calibration Pump is a dual pressure source with the ability to easily adjust and stabilize. This calibration pump possesses both *5% vacuum and pressure ***0psi; uses air as the media, and can adjust the pressure easily and stably. Since it is attached inner gas-liquid isolator and shut-off valve (for releasing dirt), ConST**2 is totally free from humidity and ***** The adjusting resolution is up to *0 Pa (0.1 mbar). These features make the ConST**2 ideal for calibrating pressure transducers, precision pressure gages, and other pressure instruments. FEATURES Pressure up to **0bar by air Both vacuum and positive pressure is available. High pressure resolution and high pressure stability Easy to get the high pressure by using long and tough pressure lever SPECIFICATIONS Media: Air. Generated Pressure Range: *4psi (0.*5bar) vacuum to ***0psi (**0bar) positive pressure Pressure Resolution: *0 Pa/ 0.1 mbar Material: Ram/adapters: **6 SS; Body: Steel/aluminum; Seals: Buna-N. Test Gage Connection: M*0*1.5; Reference Gage Connection: M*0*1.5 Dimensions: Height: *6.*3 (**0 mm); Base: **7.*4(**5 mm) x **4.*2(**5 mm). Weight: 3.*1 lb (7.5 kg). PRECAUTIONS 1. Please donât add any oil or water into the pipeline. 2. To avoid damaging the airproof surface, please donât operate the shut-off valve aggressively. 3. This product can not directly calibrate pressure meters that are used under acid or alkali conditions. If necessary, you must make sure the meters are cleansed by CCl 4 Solvent or melted oil spray to avoid any corrosion damage to the test pump. MAINTENANCE Upon final installation of the Model CONST***2 Low Pressure Calibration Pump, no routine maintenance is required. A periodic check of system calibration is recommended. The Model CONST***2 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a

Send a direct inquiry to this supplier

至:

Mr. Tony < Beijing ConST Instrument Technology Inc. >

我想知道: