离岸价格
获取最新报价|
Minimum Order
位置:
-
最小订单价格:
-
最小订单:
5 Piece
包装细节:
standard package paper carton
交货时间:
2-4 weeks
供应能力:
-
付款方式:
T/T, L/C
联系人 Ms. Nancy
Yushan, Beijing, Beijing
R3S series temperature transmitter, used for industrial automation system, receiving thermal resistance signal input from industrial field, converting it to analog output to corresponding temperature with the same proportion, isolating and conveying to DCS/PLC, realizes the temperature gathering and transmitting in industrial field, meanwhile meet with signal types matching, isolation, interference rejection and improve the system stability function between DCS/PLC. It contains a variety of combination forms like one-input & one-output, one-input & two-output, two-input & two-output, etc. Width of the shell is only *2mm, which can satisfy the high-density requirements of on-site installation.
General specifications |
|
Construction |
Ultra-thin terminal connections |
Connect |
Phoenix terminals M3 screw connection |
Wire diameter |
0.**2.5mm2 |
Tightening |
0.**0.6Nm |
Housing material |
Fire resin |
Protection grade |
IP*0 |
Mounting |
EN****5 standard symmetrical *5mm DIN rail |
Dimensions |
W*2 x H*5 x D**0 mm |
Weight |
approx. **0g |
Input specifications |
|||
Input voltage range |
*8V~*0V DC (*4V DC feed) |
the Power of full-load |
≤2W |
Absolute maximum input voltage |
*0VDC |
the Power of no-load |
/ |
Power reverse-phase protection |
Yes |
Power overload protection |
Yes |
Input signal specifications |
|||
Input signal range |
4~*0mA (*4V DCCrushing electricity) |
||
Input resistance |
≤**0W |
||
Absolute maximum input |
Current signal: ≤**0mA (Take over-current protection) |
||
Isolation power |
no-load *4VDC±5%, *0mA output ≥ *0VDC |
||
Isolation power overload |
≤**0mA (with over-current/short circuit protection) |
||
Output signal specifications |
|||
Output signal range |
4~*0mA, 0~*0mA, 1~5V, 0~5V, 0~*0V etc. output signal type |
||
Output signal resistance
|
0/4~*0mA output: 0~**0W (with short circuit protection) |
||
|
0~*0mA output: 0~***0W (with short circuit protection) |
||
|
0/1~5V output: ≥**0KW (with short circuit protection) |
||
|
0~*0V output: ≥1MW (with short circuit protection) |
Typical application:
Ø Field need to transfer the thermal resistance or potentiometer signal into isolated standard signal.
Ø Field existing grounding potential difference.
Ø Field existing heavy electromagnetic interference.
Ø Protecting DCS or PLC system.
Distributing one signal in two ways.