看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Etran Input reactor for AC drive

Sell Etran Input reactor for AC drive

离岸价格

获取最新报价

95 / Piece

|

Minimum Order

位置:

Zhejiang China

最小订单价格:

最小订单:

4 Piece

包装细节:

carton or plywood box

交货时间:

two weeks

供应能力:

300 Piece per Day

付款方式:

T/T, L/C, Western Union

现在联系
免费会员

联系人 Mr. Eric

Room 2608 of New Youth Plaza, No.8 Jiashan Road, Hangzhou, Zhejiang

现在联系

详情

Inverter and converter in use, often by the surge current and surge voltage from the impact, would seriously damage the inverter and the governor's performance and service life, so to install in front of the input reactance device, to suppress the surge voltage and surge current, protect the inverter and the governor, extending its life and prevent harmonic interference, and because the inverter and the governor's approach is the use of variable frequency speed control, so governor, he often will produce high-order harmonic distortion and the resulting waveform will affect the normal use of the device, this shall be the installation of a line input reactor to improve the inverter power factor and harmonic current suppression, filter harmonic voltage and harmonic current and improve power quality.

I. Features

1 power supply for other devices have significant interference (interference, over-voltage);
2 power supply voltage phase imbalance> 1.8% of rated voltage;
3 low impedance line (power transformer for the drive rating more than *0 times);
4 in a line to reduce line current and the installation of a large number of frequency;
5 Enter the reactor using cosφ (power factor) correction capacitors or power factor correction unit.


Second, the technical parameters

1 Insulation resistance: ***0VDC insulation resistance ≥ **0MV

(2) Dielectric strength: core - winding ***0VAC/*0Hz/5mA/*0s flashover breakdown (factory test)

3 Enter reactor noise: less than *5dB (horizontal distance from the reactor with point 1 meter test)

4 Rated voltage: **0V/*0Hz or **0V/*0Hz

5 protection rating: IP*0 6. Insulation class: F or above

7 insulation: dry-type reactor 8 with or without core: core-type reactor
9 Certification: CE *0. Usage: input reactor
*1 Rated current: 3 ~ ***0 (A) *2. System Voltage: 0.*9/1.*4 (KV)

Send a direct inquiry to this supplier

至:

Mr. Eric < Zhejiang Etran Electric Co., Ltd. >

我想知道: