看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell BS 476: Fire test to Building Material - Fire Propagation

Sell BS 476: Fire test to Building Material - Fire Propagation

离岸价格

获取最新报价

|

Minimum Order

位置:

-

最小订单价格:

-

最小订单:

-

包装细节:

-

交货时间:

-

供应能力:

-

付款方式:

-

现在联系
免费会员

联系人 Mr. Ron

Jiahe Rd, Xiamen, Fujian

现在联系

详情


BS **6 Fire Test to Building Material – Standard 

BS **6: Fire Tests on Building materials and structures – Method of test for fire propagation for products

 

BS **6 Fire Test to Building Material – Standard Brief 

This Part of BS **6 specifies a method of test, the result being expressed as a fire propagation index, that provides a comparative measure of the contribution to the growth of fire made by an essentially flat material, composite or assembly. It is primarily intended for the assessment of the performance of internal wall and ceiling linings.

 

BS **6 Fire Test to Building Material – Test Mehod 

 Once a satisfactory repeatable calibration is achieved, allow the apparatus and specimen holder to cool to ambient temperature, remove a specimen from the conditioning chamber and mount it in the specimen holder. Where necessary, back it with non-combustible packing, previously conditioned, to ensure that when the holder is clamped on to the combustion chamber, the face of the test specimen is in contact with the walls of the combustion chamber.

Carry out the test procedure e.

 Decomposition of the specimen during test may result in the formation of soot deposits on the thermocouple hot junctions, which may interfere with the accurate measurement of gas temperatures. To minimize this effect, clean the thermocouples at least *0 s before every temperature reading after the first 3 min of test, by removing them from the chimney and cleaning them with fine wire wool or a fine wire brush, then replacing them.

  Record the mV output from the thermocouples of the flue gases throughout the duration of the test.

   Note the actual mV output at the intervalsand the mV rises above the initial m V reading.

  Calculate Es, the output from the thermocouples for the test specimen, in mV, by the same method specified for Ec and convert it to temperature rise for the flue gases

  The determination of the fire propagation index requires results from three specimens, but if any specimen exhibits the behaviour described, test up to a maximum of five specimens in an attempt to obtain three valid test results

 

BS **6 Fire Test to Building Material – Reference Standard 

 BS **6Fire tests on building materials and structures

 BS ****3Fire tests on building materials and structures. Classification and method of test for external fire exposure to roofs

 BS ****4Fire tests on building materials and structures - Part 4: Non-combustibility test for materials

 BS ****5Fire Tests on Building Materials and Structures Part 5: Method of Test for Ignitability

 BS ****6Fire tests on building materials and structures — Part 6: Method of test for fire propagation for products

 BS ****7Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products

 BS *****1Fire tests on building materials and structures — Part *1: Method for assessing the heat emission from building materials

 BS *****2Fire tests on building materials and structures — Part *2: Method of test for ignitability of products by direct flame impingement

 BS *****3Fire Tests on Building Materials and Structures Part *3: Method of Measuring the Ignitability of Products Subjected to Thermal Irradiance

 BS *****5Fire Tests on Building Materials and Structures Part *5: Method of Measuring the Rate of Heat Release of Products

 

Send a direct inquiry to this supplier

至:

Mr. Ron < Ecosafene Product Service Co., Ltd >

我想知道: