离岸价格
获取最新报价4500 ~ 5500 / Piece ( Negotiable )
|Minimum Order
位置:
China
最小订单价格:
最小订单:
1 Piece
包装细节:
standard package for international transportation
交货时间:
within 7 days upon receipt of the payment
供应能力:
100 Piece per Month
付款方式:
T/T
联系人 Ms. Anna
Zhongxing Avenue, Anqing, Anhui
Based on ergonomics of the design, structure concise and fluent, mobile, lightweight comfortable. Microcomputer control of the ventilator imported sensors and components, and production processes to ensure that rigorous internal quality products, folding bellows breathing mechanical ventilation system so that security situation, intuitive. High-precision anesthesia evaporators to ensure that the concentration of anesthesia output accuracy. Power transmission and gas metering system to ensure the safe and reliable gas supply. The aircraft brought together a number of modern technologies, is a fine performance, functionally complete anesthesia machine.
*This machine uses in respiratory control , respiratory intensive care , 5.*-inch high clear display, pressure-time wave and Velocity-time wave to monitor respiratory condition Multi-directionally.
*The high-precision evaporator has the stable output concentration with pressure, temperature, and flow automatic compensation; Choose two among Enflurane, Isoflurane,Sevoflurane and Halothane for a matching.
Main Technical Parameters
Part of Anesthesia Machine
*Console high-strength engineering plastic rack, light, beautiful and corrosion resistance
*Scope adult, child
*Gas source O2、N2O:0.3~0.5MPa
*Flow meter O2: 0.1~*0L/min 1.1~*0L/min
N2O: 0.1~*0L/min 1.1~*0L/min
*O2、N2O oxide linkage and nitrous oxide Truncation device
When use nitrous oxide, oxygen concentration>*5%; when the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
*Rapid oxygen flow *5~*5L/min
*Vaporizer it has the function of pressure,temperature, and flow automatic compensation. The regulation range of evaporator concentration is 0~5vol%. Choose two among enflurane, isoflurane and sevoflurane for a matching according to the demands of customer.
*Low oxygen pressure alarm
It will be alarmed when the oxygen pressure < 0.2MPa
*Respiratory circuit work mode all close. semi-close. semi-open APL: 0.5~7KPa
*Bellows breathing adults and child bellows tidal volume range:0~***0ml child bellows tidal volume range:0~**0ml adults、children bellows、children loop are arbitrary choice for users.
Part of Ventilator
*Display mode 5.*-inch high clear display,
*Ventilation mode IPPV SIPPV
SIMV PEEP MANUAL SIGH
*Ventilation parameters
Tidal volume *0~***0ml Frequency 4~*0bpm
I:E 2:1~1:8 Trigger sensitivity *1.0~*0.1Kpa
PEEP 0~1.0Kpa Pressure Control 1~6Kpa SIGH 1.5 breath times
*Ventilation monitoring parameters
Tidal volume. ventilation. IPPV ratio. breath /expiratory
Ratio. peak pressure . pressure-time wave. velocity-time
Wave. total
respiratory rate. airway pressure wave. PEEP.breath pressure
trigger.
*Monitoring oxygen concentration *1%~**0%(choose and
match)
*Security Alert System (choose and match)
Oxygen Concentration alarm
Upper limit setting range *0%~**0%
Low limit setting range *5%~*0%
Airway pressure alarm
Upper limit setting range 1~6Kpa
Low limit setting range 0.4~2Kpa
Alarm minute ventilation
Upper limit setting range 3.0~*0L/min
Low limit setting range 1~*0L/min
Asphyxia alarm the machine will give sound and light alarm if there is no tidal volume input in *5s
Power failure alarm
*Power AC **0V±*0% *0Hz±1Hz
UPS. Battery. (choose and match)
*Manipulators (choose and match)