离岸价格
获取最新报价|
Minimum Order
位置:
China
最小订单价格:
-
最小订单:
10 Piece
包装细节:
16 pcs / carton
交货时间:
5-7 days
供应能力:
10000 Piece per Month
付款方式:
Other, Western Union, L/C, T/T
联系人 Mr. Li
No.15 Keji 6 Road,Chuangxin Haian,Tangjia High-tech Zone, Zhuhai, Guangdong
1. Use module framework. Several modules can be selected flexibly.
2. PMAC**1 provides *7 protection functions such as start overtime protection, overload protection, overcurrent protection, phase failure protection, current unbalance protection, earth fault/leakage current protection, short circuit protection, underload protection, external fault protection, overvoltage protection, undervoltage protection, under power protection, phase sequence error protection, EEx e overload protection, temperature (PTC/NTC) protection, analog input protection.
3. Provides measurements of three phases current, three phase /phase voltage, zero phase sequence current, active power, reactive power, power factor, frequency, and active energy measurements.
4. Provides protection, direct starter, reversing direct starter, star/delta starter, and autotransformer starter etc motor starting control modes.
5. Main module provides 9 DIs for start, stop and reset etc. signals input. If more DIs are needed, an extended digital module can be selected. Some of the DIs are programmable.
6. Main module provides 5 DOs to meet varies of starting control modes and protection action. If more DOs are needed, an extended digital module can be selected. Some of the DOs are programmable.
7. Provides 4~*0mA analog output for DCS.
8. 8 trip events can be stored in non-volatile memory.
9. Through an extended analog module, 2 analog input or 1 analog and 1 hot resistance input can be added.
*0. Small size and compact configuration.
*1. Easy installation. Proper for *5mm DIN rail.
PMAC**1 Motor Protection Relay and Motor Controller With Following Features:
1. Use module framework. Several modules can be selected flexibly.
2. PMAC**0 Low Voltage Circuit Breakerprovides *2 protection functions such as start overtime protection, overload protection, overcurrent protection, phase failure protection, current unbalance protection, earth fault/leakage current protection, short circuit protection, underload protection, external fault protection, overvoltage protection, undervoltage protection, under power protection, phase sequence error protection, EEx e overload protection, temperature (PTC/NTC) protection, analog input protection.
3. Provides measurements of three phases current, three phase /phase voltage, zero phase sequence current, active power, reactive power, power factor, frequency, and active energy measurements.
4. Provides protection, direct starter, reversing direct starter, star/delta starter, and autotransformer starter etc motor starting control modes.
5. Main module provides 9 DIs for start, stop and reset etc. signals input. If more DIs are needed, an extended digital module can be selected. Some of the DIs are programmable.
6. Main module provides 5 DOs to meet varies of starting control modes and protection action. If more DOs are needed, an extended digital module can be selected. Some of the DOs are programmable.
7.Provides 4~*0mA analog output for DCS.
8. Through an extended analog module, 2 analog input or 1 analog and 1 hot resistance input can be added.
9. Small size and compact configuration.
*0. Easy installation. Proper for *5mm DIN rail.
1. Protection:
Protection | PMAC**2 | PMAC**1 |
start overtime | √ | √ |
Over load | √ | √ |
Over current | √ | √ |
Phase failure | √ | √ |
Current unbalance | √ | √ |
Short circuit | √ | √ |
Earth fault | √ | √ |
Under load | √ | √ |
External fault | √ | √ |
Leakage current | optional | optional |
Temperture ( PTC/ NTC) | optional | |
Over voltage | optional | optional |
Under voltage | optional | optional |
Under power | optional | |
Phase sequence error | optional | |
EEx e overload (tE) | optonal | optional |
Analog input | optioanl |
2. Measurement:
Parameters | PMAC**2 | PMAC**1 |
3 phase current, neutral current, unbalance rate | √ | √ |
3 phase voltage | optional | optional |
active / reactive power | optional | optional |
leakage current | optional | optional |
power factor | optional | optional |
frequency | optional | optional |
active energy (kwh) | optional | optional |