3 Gong Second Road Linkou District, New Taipei City, Other
现在联系
详情
Output from 6W to **0W.
Single phase and three phase are available.
Four pole standard and high speed bipolar types are
available.
Both lead wire and terminal box connection is available.
1.Insulation resistance: Use a DC**0V high resistance gauge to
measure the coil of motor and it's an outer shell when motor
running in normal temperature and normal humidity, its value
should be above **0MΩ.
2.Insulation pressure endurance: Apply *0Hz, 1.5kV at the coil
of motor and it's an outer shell for one minute without and
extraordinary phenomenon when motor running in normal
temperature and normal humidity.
3.Temperature arises: Install two reduction gears or radiation
plate of the same class at the motor. After rated running,
test the coil by resistance method. Its value should be less
than *0°C.
4.Insulation Class: Class B (**0°C).
5.Overheat protection: Over heat shut down system.
6.Environment temperature: **0°C~**0°C.
7.Humid around the environment: Below *5% (No frosting
happen).