离岸价格
获取最新报价1.9 ~ 3.5 / Square Meter
|Minimum Order
位置:
Hebei
最小订单价格:
最小订单:
1000 Square Meter
包装细节:
100pcs/pkg, 50pcs/pkg
交货时间:
Within one month after signing the contract
供应能力:
400000 Square Meter per Month
付款方式:
PayPal, L/C, T/T
联系人 Ms. Judy
Arcadia Huajingyuan 1-2-101, Beihuan Road, Langfang, Hebei, China, Langfang, Hebei
High sensitive subtractive color PS plate, high sensitivity, high resolution,
excellent dot reproduction ability, wide developing tolerance, moderate
grains. Attached vacuum protective layer, pumping more real and more
faster during exposure.
Baking condition: ***0W Iodine-Gallium lamp, light distance is 1m, suggested exposure time is ****5 seconds.
Grains forming style: electrolyzed
Print PS plate adopts the manufacturing technics of multi-layer grains and grain restoration which are inthe
leading level of the world. The grains have very good gradation, fine and closely, also well-distributed. The
plate has good feature of anti-pollution, high resolution, good run length, also has short exposure time,
good tolerance, and quick development. There will be a better effect with correct exposing and developing
operation.
Recommended Using Method (only for reference):
1. Exposure:
1.1 The photosensibility of Huarui positive PS plate is **5mj/cm², when in real operation, customers need to
fix an exposure time reasonably according to the type of light source, power, degree of new or old, light
distance ,and other detailed conditions. According to our technician's power test to the exposurelampof
Sunshine Color Printing Company, it showed that the lamp equivalent is 2KW, so there is a suggested
exposure time of ****0 seconds.
1.2 If using the Thirteen-Levels Continuous Grey Gradient Ruler to fix the best exposure time, color plate
should expose to 0.6 (level 4), proofing plate should expose to 0.*5 (level 3).
1.3 After fixing the exposure time initially, operator need to expose and develop the plate normally, in the
mean time, observe if screen2% and resolution ratio*0μ are perfect, also to amend or confirm the exposure
time in time.
1.4 Example: 4KW Iodine-gallium lamp, 1.0m light distance, new lamp, the correct exposure time should be
*5±5 seconds.
2. Development:
2.1 Dilution ratio of developer: medical solution: water=1:4 (machine development)
medical solution: water=1:6 (manual development)
2.2 Development temperature should be controlled at *5°C±2°C. With a too high temperature, the oxide
coating of plate substrate will be destroyed; the plate substrate will become indistinct; the run length of plate will decrease. But with a too low temperature, there will be a short of development, so that have remains on the plate.
2.3 Development time is *0 seconds, with the increasing of development plates, the developer's potency will
decline, so the operator need to extent the exposure time properly, and pay attention to supplement, also
change it periodically. The replacement of developer doesn't have a rule of quantity, so customer should
observe the amount of remains on the plate, and change developer according to the actual situations in time.Because the developer is oxidized in air continuously, it will be oxidized even doesn't be used, it is also a
reason for the decrease of developing ability. So the advice is to observe the condition of plate surface in
every other ****0 pieces.
//