看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。
点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Wholeale pen type waterproof electrode replaceable PH meter LH-P682

Wholeale pen type waterproof electrode replaceable PH meter LH-P682

离岸价格

获取最新报价

18.4 ~ 26.4 / Piece ( Negotiable )

|

Minimum Order

位置:

Zhejiang China

最小订单价格:

最小订单:

25 Piece

包装细节:

180*65*33mm, 140.0g, can be customized

交货时间:

within 3 days after receiving the payment

供应能力:

1000 Piece per Month

付款方式:

T/T, L/C, Western Union, Money Gram, PayPal, Other

现在联系
免费会员

联系人 Mr. zhou

NO.355 KenShan Eatern Road JiangGan Region, Hangzhou, Zhejiang

现在联系

详情

Wholesale pen type Waterproof PH Meter LH-P**2

1. Technical data
Measuring range
0.****4.*0pH
Resolution
0.*1pH
Accuracy
±0.*5pH
Calibration
1 point
Power
4*1.5V alkaline
Working condition
***0°C, RH no more than *5%
Dimension
**2**6**6mm
Net weight
*3g
Meter’s complete kit
LH-P**2 PH meter, screw driver, batteries inside, operation manual, protective box
Optional accessories
P**2 sensor, PH4.*0, 6.*6, 9.*8 buffer solution or powder
 
2. Feature: probe BNC plug, small size, ATC, Replaceable sensor, Low battery indicate, high accuracy
3. Operation
1. Remove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water.
2. Turn the tester ON by pressing the ‘ON/OFF’ button.
3. Immerse into solution up to the max immersion level.
4. Stir gently and wait until the display stabilizes.
5. After use, Turn the tester off by pressing the ‘ON/OFF’ button, use the water clean the electrode and replace the protective cap.
Do not use distilled or deionized water for storage purposes.
Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.
4. Calibration
1. Immerse the tester up to the maximum immersion level in pH 6.*6 buffer solution.
2. Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.*6.
3. Immerse the electrode in PH 4.*1 or PH 9.*8 the standard buffer solution of borax. Until the display shows “3.***4.*6PH” or “9.***9.*3PH”.
Always use fresh buffers for calibration.
Important the instrument must be re-calibrated whenever.
1. The electrode or battery has been replaced.
2. Approximately one mouth has passed from the last calibration.
3. The electrode has been used in particularly taxing conditions.
4. The utmost accuracy is required.
5. Battery replacement
When the battery symbol appears on the display, this indicates a low battery and only 1 hour of continuous use remain. Though the unit may continue to function, the accuracy of the unit will be affected beyond the 1 hour twist open the battery compartment lid. Remove old batteries and replace with fresh ones noting polarity as show in battery compartment.
 
6. Electrode replacement 
1. Remove the protective cap.
2. Unscrew the plastic ring on the top of the electrode.
3. Pull out the electrode and replace it with a new one. Make sure the gaskets are in place before screwing back the ring
 
7. Warranty
These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase. If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either dealer or our offices, and the repair will be effected free of charge.
 
More products, please contact us,
We are a manufacturer which has a long history of focusing on water test products, including refractometer, PH ORP TDS conductivity DO and chemistry in water test product, we are seeking local wholesaler to cooperate, welcom to ask for catalogue and quotation.

Send a direct inquiry to this supplier

至:

Mr. zhou < HangZhou Lohand Biotechnology Co., Ltd. >

我想知道: