Wholesale freezing point of antifreeze refractometer

Wholesale freezing point of antifreeze refractometer

离岸价格

获取最新报价

19.35 ~ 25.81 / Piece ( Negotiable )

|

Minimum Order

位置:

Zhejiang China

最小订单价格:

最小订单:

10 Piece

包装细节:

204*78*54mm, 158g, protective sofr skin box or plastic box

交货时间:

within 3 days after receiving the payment

供应能力:

1000 Piece per Year

付款方式:

T/T, L/C, Western Union, Money Gram, PayPal, Other

现在联系
免费会员

联系人 Mr. zhou

NO.355 KenShan Eatern Road JiangGan Region, Hangzhou, Zhejiang

现在联系

详情

LH-T*0 Freezing Point of Antifreeze and specific gravity of Battery fluid detector
These models can be used for measuring the freezing point of either ethylene glycol or propylene glycol which used widely in vehicle as antifreeze, based cooling system, and checking the strength of electrolyte solution batteries.
 
1. Technical data
LH-T*0
Measuring range
Resolution
Accuracy
Antifreeze
0°C~**0°C
5°C
± 2.5°C
Battery fluid specific gravity
1.*0~1.*0
0.1
± 0. 1
Cleanout fluid
0°C~*0°C
*0°C
 
1. Prism, 2.Cover plate, 3.alibration, 4.Mirror tube, 5. Eyepiece (Adjusting ring of diopter)
 
2. Operation:
1. Prepare: Aim the front end of the refractometer in the direction of a bright light, and adjust the adjusting ring of diopter (5) until the reticle can be seen clearly.
2. Calibration: Drop one drop of standard solution on the bright surface of the reference block. Open the cover plate (2), stick the reference block on the surface of the prism, and press it lightly with your hand, so that it can not slide down. Rotate and adjust the calibration screw (3) to make the light/blue boundary coincide with reference line.
3. Measurement: Open the cover plate (2), clean the surface of prism with a piece of soft cotton flannel, Drop 1~2 drops of the solution to be measured. Close the cover plate, and press it lightly, then read the corresponding scale of light and dark boundary. The reading is thefreezing point or specific gravity of the measured solution.
4. Storage: Clean the surface of prism and cover plate with moist gauze, and it should be stored carefully.
 
3. Attention and maintenance
1. Adjustment for the null liquid and specimen should be in the same temperature. Once the temperature moves greatly, the null point should be adjusted once per *0 minutes.
2. To avoid using water to wash the instrument, so as to avoid water entering the inside of the instrument.
3. As a precision optical instrument, handle it gently and take good care of it. Do not touch or scratch the optical surface. Please keep it in a dry, clean and non-corrosiveness environment, to prevent the surface from turning mouldy and foggy. Please avoid strong shock during transportation.
4. If the consumers use the instrument in accordance with the mentioned method of usage, the optical performance should not be changed.
 
4. Temperature compensation
The reference of temperature is *0°C. In operation, the temperature should be made according to the correcting table. ATC is mounted with Automatic Temperature Compensation, it has the extra function, it enables user concentrate on measurements without worrying the temperature. Compensation range is *0~*0°C.