Detailed Description of Medical Oxygen Regulator
(series)
1. Input pressure: *5Mpa
2. Output pressure: 0.**0.3Mpa
3. Automatic Discharge Pressure of The Safety Valve:
0.*5+_0.*5Mpa
4. The Range of Flow: ***5L/min
5. Connection Thread: G5/8, male
6. Mainbody: Copper
7. Structure: Piston type
8. Packing: *0PCS/CTN (color box) or other
9. G. W. /N. W.: *0/*9kg
*0. Dimension: *1× *2× *6cm
Medical Oxygen Regulator
The flowmeter with humidifier is used in reducing gas pressure and
adjusting the gas volume, which rescue patient and treat as oxygen
therapy by hospital. Also may make using of other gas reduced
pressure and the control flow.
Product main feature:
The product has artistic outlook, and flow control comfortable and
stable.
The reductor is adjustable; The structure is unique, and the
performance is reliable.
The stainless steel floater and the orange substrate flowmeter have
a especially visual effect;
The international standard connect way, is suitable for all kinds
of gas bottle installation.
Range of application
Give oxygen for first-aid or oxygen uptake for the people who are
lack of oxygen.
How to use
1. Open the valve of oxygen cylinder after connect the screw nut of
air intake closely.
2. Connect the oxygen pipe to the oxygen outlet
firmly.
3. Demount the humidifying cup(anti clock wise rotation), put some
distilled water in (purified water or plain boiled water can also
take place), the water quantity should be between the bottom and
top tick mark, then tighten up the bottle cap to the humidifying
cup(clockwise rotation).
4. Rotate the flow regulating valve to the rate you need (anti
clockwise to up, clockwise to down, till to close), then put it to
nose to use.
5. Close the valve of oxygen cylinder firstly while not using, then
close the flow regulating valve until the pointer of oxygen
manometer return to zero.
Attention
1. Make sure there is no ash on the connector and check the screw
thread, then install the inhalator.
2. Make sure the flow meter is vertical to the floor and flow
regulating valve is closed, then open the valve of oxygen cylinder
slowly, regulate the flow after the high pressure gauge shows the
pressure of the oxygen cylinder.
3. No drastic shock, far away with the corrosive substance, and no
oil stain.
4. The set screw of the safety valve can't be rotated at random,
non-professional people are forbidden to
dismount.
Condition for storage
Should be kept in the environment whose humidity is less than *0%,
no corrosive gas and drafty.
Quality guarantee period
We will fix or change the oxygen inhalator within a half and a year
after the day of living the company when it can't proper
functioning, it should be under the condition of obeying the rule
of storage and using.
Specification
1. Forbid to use the Buoy Type Oxygen Regulator to take oxygen
atomization treatment.
2. Forbid to dismount by yourself.