看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
belt scales

belt scales

离岸价格

获取最新报价

200 ~ 500 / Piece

|

Minimum Order

位置:

China

最小订单价格:

最小订单:

1 Piece

包装细节:

cartoon box

交货时间:

20days

供应能力:

500 Piece per Week

付款方式:

T/T, L/C, Western Union, Money Gram

现在联系
免费会员

联系人 eva

Shenzhen, Guangdong

现在联系

详情

Features:

  1. Feedrate Measurement and Control for  Conveyor Belt Scale and Weigh Feeder.
  2. 1 Analog Input.
  3. 2 Analog Output
  4. 3 Digital Input
  5. 7 Digital Relay Output
  6. 1 Pulse Output
  7. Modbus Communication ( Independent RS**2 and RS**5 Port)
  8. AC**0V Power Supply. 
  9. DC*4V Power Supply is Optional
  10. VFD Display. LCD Display is Optional
  11. Language Selective. English is Default, Second Lauguage can be Chinese
  12. Integrated Diagnostics and Self-testing Functions
  13. Digital Electronics. Provide Accurate, Drift-free Performance

Dimensions of the Belt Scale Controller JY**0B1

 

 

 

Technical parameters of the controller

Inputs

Static & Dynamic Calibration
Static Calibration uses load cell sensitivity and load cell capacity to calibrate the weight signal. Dynamic calibration allows calibration of weight when the belt is running knowing the platform weight(kg) or the belt loading (kg/m)
Flowrate  Set point
The setpoint is the flowrate of material the belt conveyor is carrying. The controller can control the local setpoint ,which is set via the keypad or remote analog input.
Digital Inputs
There are 3 digital inputs. Terminal X*0 (1 ,2) is used to confirm the events.  Terminal X9 (1,2) is used to stop the controller and terminal X9(3,4) is used to run the controller.s
Tacho input
The tacho input is used to measure the speed of the belt. To make a calibration, you need to run the belt at a constant speed to get a constant tacho input.
JY**0B1 can accept a wide range of speed sensors, including proximity switch ,Namur switch, stepper motor and encoder.
Zeroing 
The weight of the unloaded belt is averaged over one or more complete belt revolutions and the resulting value is kept as the dynamic zero.
While in zeroing, any small drift in the weight measurement or materials build up on the weigh platform is automatically zeroed out. This ensures that with no products on the belt ,a zero flowrate is recorded.
Limits
The low and high limits have adjustable setpoints which may be programmed to operate on any internal signal.
Batching
The controller can be used to batch out a desired weight by stopping the conveyor when the weight has pass the weight platform. A pre-act weight can be adjusted to shut off the conveyor before the target weight is reached allowing time for the conveyor to stop and allowing the correct batching weight to be reached. 
Loop Control
The controller compares the flowrate with the setpoint . A proportional/integral ( PI ) control technique alters the analog control output to maintain the flowrate at setpoint. It makes the belt scale get the desired flowrate very quickly and also make it respond to changes in setpoint rapidly.
Events Collection
Process events are collected for operation with external equipments.( Speed sensor etc.)

Internal Signal

The total of material
The controller incorporates a totaliser which totalise the weight of material through the belt scale. The totaliser can be reset to zero easily. A pulse output is available to operate external counters. The total is retained after a power failure.

Output

Analog control output
An analog control output is used to drive a frequency inverter to change the speed of electric motor in order to get vary the belt speed.
Analog feedrate output
An analog feedrate output reprensents the feedrate of the belt scale and can be connected to other instruments.
Analog I/O Scaling
The range of analog outputs can be adjusted over the full 0 to *0 mA. A voltage output can be easily acquired by connecting a resistor to the output.
The analog feedrate output can be changed into an analog output that represents belt speed or belt loading(kg/m)
Digital Relay Output
There are 7 digital relay outputs to operate from 7 internal signals, such as start/stop the electric motor, start/stop the pre-feeder and so on

Communications

RS**2 and RS**5 ports are available. They are used to connect to some systems. The protocol is either ACSII output for example to drive a printer or Modbus for interactive communications. Baud rate and node address are programmable.

General

Housing
Dimension
Weight
Supply Voltage
Power
Working Temperature
Humidity
Linearity
Accuracy
Protection Class
Range of Feed Rate

Brushed Aluminum
**8(W)x **5(D)x *6(H)mm
2.5 Kg
AC**0V (*5V***5V),  *0Hz
*0W
**0°C**0°C   
≤ *0%RH
0.*1FS
0.1%
IP*6
0.*********9.9 t/h

Load Cell Input

Excitation
Signal Process Rate
Non-lineartiy
Type of Load Cell

9V DC±*0%, **0mA Maximum Current
**0Hz
0.*1%FS
*-Wired LoadCell and *-Wired Load Cell

Speed Sensor Input

Excitation
Speed Pulse Range
Type of Speed Sensors

DC*4V
*****0Hz
Proximity Switch,  Namur Switch,
Encoder and Stepper Motor

Output

Analog Output
Digital Relay Output
Pulse Output

2 ports, 0/***0mA
7 ports , **0V/1A
1 port, *4V

Communication

Interface
Baud Rates
Protocol

RS**2 & RS**5
***0,***0,****0 and ****0
Modbus RTU

Send a direct inquiry to this supplier

至:

eva < zhuohe intromentation co. ltd >

我想知道: