看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
GD-261 Pensky-Martens Closed Cup Flash Point Tester

GD-261 Pensky-Martens Closed Cup Flash Point Tester

离岸价格

获取最新报价

3 ~ 7 / Set ( Negotiable )

|

Minimum Order

位置:

-

最小订单价格:

最小订单:

1 Set

包装细节:

wooden packing with foam to protect

交货时间:

15 days

供应能力:

100 Set per Month

付款方式:

T/T, L/C, Western Union, Money Gram

现在联系
免费会员

联系人 Rita

NanPing West Road, ChongQing, Chongqing

现在联系

详情

I**-Brief Introduction

              1.This instrument is designed and made as per the the standards GB/T*******8
              2.Test Method for Flash Point of Petroleum Products by the Pensky-Martens Closed Cup Method and ASTM D*3.
              3.It is suitable to determine the closed cup flash point of petroleum products, which is expressed as the lowest temperature when a sample is heated in a closed cup under the stipulated condition until the mixture of its vapor and air contacts flame and appears flash.
 
II**-technical features of   Pensky-Martens Closed Cup Flash Point Tester
  1.This instrument is designed correspond with the requirements of GB/T*******8.
  2.The heating power is continuously and stepless adjustable. The power is shown visually by   voltmeter.The temperature control mode is advanced and reasonable.
  3.The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
  4.Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting units.
 
III**-Specifications and parameters OF  Pensky-Martens Closed Cup Flash Point Tester
   1.Power supply:AC (**0±*0%)V, *0Hz.
   2.Heating device::The heating power is continuously adjustable from 0 W to **0W.
   3.Rate of sample’s heating up::(1~*2)°C/min;Controllable and adjustable.
   4.Electric stirring rate:(1)(*0~**0)turns/min,suitable to test procedure A.
                                     (2)(**0±*0)turns/min,suitable to test procedure B.
   5.Standard oil cup:(1)Inner diameter: *0.7mm~*0.8mm.
                                 (2)Depth: *5.7mm~*6.0mm.
                                 (3)The scribed line depth of capacity of testing oil: *3.9mm~*4.3mm.
                                 (4)Capacity of testing oil:about *0ml
   6.Igniting device:(1)Igniting source: gas(or other civilian fuels,the same below)
                                       (2)Bore diameter: 0.8mm
   7.Thermometer:Mercurial thermometer, correspond with GB/T*******8
                            (1)Scale *5°C~**0°C, division 0.5°C.
                            (2)Scale *0°C~**0°C, division 1°C.
                            (3)Scale *0°C~**0°C,division 2°C.
   8.Ambient temperature:≤ *5°C
   9.Relative humidity:≤ *5%
   *0.Power consumption of overall unit:≤ **0W