详情
Product description:
LXC**0 generator controller uses **-bit
microprocessor and embedded system control technology, precision
measuring *6 parameters, *2 programmable inputs, *5 warning
protection parameters, *5 programmable output of **1 configurable
parameters . Of which **8 can be configured from the front panel.
With LCD graphic display module can display various engine
parameters and generator parameters. Was quickly promote the use in
multiple areas, such as: small power plants, biogas power
generation, oil and power, field engineering, factory, fire pumps,
mobile base stations, and many other fields. Applies to gasoline,
diesel, natural gas, biogas and other power equipment, many
well-known domestic and foreign enterprises have been widely
supporting applications. Completely replaced DSE7X0
controller.
LXC**0: for stand-alone automated,
remotely controlled power signal generator set from the start and
stop;
LXC**0: LXC**0 based on the increase in
electricity consumption monitoring and mains / generator automatic
switching control function (AMF), especially for stand-alone
automated systems.
Product performance and features:
LXC**0: for stand-alone automated,
remotely controlled power signal generator set from the start and
stop;
LXC**0: LXC**0 based on the increase in
electricity consumption monitoring and mains / generator automatic
switching control function (AMF), especially for stand-alone
automated systems. Its main features are as follows:
1, using **-bit ARM microcontroller,
hardware integration and high reliability is further
enhanced;
2, the liquid crystal display LCD is
**8x*4, with backlight, Chinese, English and other languages
optional interface operation, and can be on-site to choose, easy
commissioning test machine;
3, with advanced networking features,
via GSM mobile network and Internet connectivity, the network in
any place can remotely monitor;
4, especially for the rental industry to
provide the perfect solution for management: leasing out via PC
remote management unit that monitors all operating parameters (oil
pressure, water temperature, voltage, current, power, etc.), you
can change the configuration at any time to protect the unit
improperly applied, can record **0 detailed fault information,
including: failure of key parameters of time, because, when the
voltage, current, power, oil pressure, water temperature, etc., and
ready to be uploaded to the monitoring machine. Another multi-level
password management to facilitate the lease term
management;
5, with SMS function, you can
automatically send an alarm message to five phone numbers set the
alarm when the generator set, you can also control the turbine
generator set and access status via SMS;
6, with RS**5 communication interface,
MODBUS protocol can be implemented using the "three remote"
feature;
7, control and protection functions:
diesel or natural gas generator set automatic start / stop switch
on or off (ATS switch) and perfect protection fault display
function;
8, parameter setting functions: allows
the user to change settings on its parameters, and memory in the
internal FLASH memory, when the system is powered down is not lost.
Most of the parameters can be adjusted from the controller front
panel, all parameters can be used to adjust the PC via RS**2
interface can also be used to adjust the PC via RS**5
interface;
9, a variety of temperature, pressure
and oil level sensor curve can be used directly, and can customize
the sensor curve;
*0, a variety of start conditions (speed
sensors, hydraulic, power generation) optional;
*1, with a history of failure record, real
time clock, timer switch (monthly / weekly / boot once a day and
can set whether to load) function;
*2, mains overvoltage, undervoltage, over and
under frequency, phase, reverse phase sequence function, power
generation has overvoltage, undervoltage, over and under frequency,
over-current, over-power, reverse power, phase , reverse phase
sequence function;
*3, three fixed analog sensors (temperature,
oil pressure, level);
*4, two programmable analog sensors can be set
to a temperature or pressure or level sensors
*5, width (8 to *5) Power supply range VDC,
able to adapt to different starting battery voltage
environments;
*6, pump unit can be used, but also can
instruct the instrument to use (only indication, alarm, relay no
action);
*7, small, extremely thin, delicate thin
control box suitable for installation
Mains
Line voltage Uab, Ubc, Uca
Phase voltage Ua, Ub, Uc phase
sequence
Frequency Hz
Generate electricity
Line voltage Uab, Ubc, Uca
Phase voltage Ua, Ub, Uc phase
sequence
Frequency Hz
Load current IA, IB, IC
Phase and total active power
kW
Phase and total reactive power
kVar
Phase and total apparent power
kVA
Phase and the average power factor
PF
Cumulative power generation kWh, kVarh,
kVAh
Temperature WT ° C / ° F to select
Display
Oil Pressure OP kPa / Psi / Bar select
Show
Fuel bit FL Unit:%
Speed (SPD): RPM
Battery voltage VB Unit: V
Charger voltage VD Unit: V
HC timer can be accumulated *5,**5
hours
Cumulative boot times
The maximum cumulative ****5 times
Specifications:
Operating voltage: DC8.0V to *5.0V (continued
supply)
Power consumption: <3W (Standard Mode: ≤
2W)
Input voltage: *2V AC - **0 V AC (PH-N) of *-phase
*-wire
*3V AC - **0 V AC (PH-N) of *-phase *-wire
Frequency: *0/*0HZ
Speed sensor voltage Vpp: 1.0 - *0Vpp
Speed Sensor Frequency: Maximum ****0HZ
Start Relay Output: *0Amp DC*8V
Programmable relay outputs: *0Amp DC*8V
Power switch programmable relay outputs: *0Amp
**0VAC
Dimensions: **9mm x **6mm x *6mm
Hole size: **4mm x **0mm
Working temperature: (**5 ~ **0) ℃ humidity (*0 to
*0)%
Storage conditions Temperature: (**5 ~ **0)
℃
Secondary electric current sensors: 5A