详情
Product description:
LXC*3X0/LXC*1X0 series controller uses **-bit microprocessor and
embedded system control technology, precision measuring *6
parameters, *2 programmable inputs, *5 warning protection
parameters, *5 programmable output of **1 can be configured
parameters. Of which **8 can be configured from the front panel.
With LCD graphic display module can display various engine
parameters and generator parameters. Was quickly promote the use in
multiple areas, such as: small power plants, biogas power
generation, oil and power, field engineering, factory, fire pumps,
mobile base stations, and many other fields. Applies to gasoline,
diesel, natural gas, biogas and other power equipment, many
well-known domestic and foreign enterprises have been widely
supporting applications. Completely replace DSE*1X0/*2X0 series
controller.
Product performance and features:
1, for the stand-alone automated,
controlled by the remote boot signal generator set from the start
and stop;
2, based on the increase in LXC***0
mains power monitoring and mains / generator automatic switching
control function (AMF), especially for stand-alone automated
systems.
3, using **8x*4 dot matrix LCD display.
Four languages: Simplified Chinese, English, Spanish, Russian
showed that *8 percent of the parameters can be set on the
controller;
4, all the parameters you can use a PC
via USB, RS**2, RS**5 interface to adjust, using the MODBUS
protocol can achieve "three remote" feature; (RS**5 is
optional)
5, with SMS function, you can
automatically send an alarm message to five phone numbers set the
alarm when the generator set, you can also control the turbine
generator set and access status via SMS. With advanced networking
capabilities, via GPRS mobile network and Internet connectivity,
the network in any place can remotely monitor; (need to install
GPRS module: LXI**0)
6, a variety of sensor data acquisition
and display mains / generator phase voltage, phase current,
frequency, active power, reactive power, power factor, power,
engine;
7, three fixed analog sensors
(temperature, oil pressure, liquid level), two programmable analog
sensors can be set to a temperature or pressure or liquid level
sensor;
8, mains overvoltage, undervoltage,
over and under frequency warning function, power generation has
overvoltage, undervoltage, over and under frequency, over current,
over-power, warning and shutdown protection;
9, has a history of failure record **0,
and can record oil pressure, water temperature, voltage, current
and other important parameters of the fault instant. When multiple
warnings, warning bar will display them in turn, facilitate the
analysis of the reasons;
*0, with a real-time clock, timer switch
(monthly / weekly / boot once a day and can set whether load)
function, to automatically maintain a purpose;
Specifications:
Operating voltage: DC8.0V continuous power
supply to *5.0V
Total power consumption: <3W (Standby mode:
≤ 2W)
Alternator Voltage Input: *0V AC***0 V AC
(ph-N) 3 phase 4 wire
Three-phase four-wire *0V AC***0 V AC (ph-ph)
*-phase *-wire
Three-phase three-wire *0V AC***0 V AC
(ph-N)
Single-phase two-wire *0V AC **0 V AC
(ph-h)
Two-phase three-wire
Alternator Frequency: *0 Hz /
*0Hz
Speed sensor voltage: 1.0 to *0V
(rms)
Speed sensor frequency: max
****0Hz
Start relay output: *6Amp controller
supply voltage output
Fuel Relay Output: *6Amp controller
supply voltage output
Programmable relay outputs 1:*6 Amp
controller supply voltage output
Programmable relay outputs 2:*6 Amp
controller supply voltage output
Programmable relay outputs 3:*6 Amp
controller supply voltage output
Programmable relay outputs 4:*6 Amp
**0VAC passive output
Open relay programmable relay outputs
5:*6 Amp **0VAC passive output
Mains relay programmable relay output 6:
*6Amp **0VAC passive output
Dimensions: **0mm x **2mm
x*7mm
Hole size: **4mm x **0mm
Current transformer secondary current:
Rated: 5A
Working conditions: Temperature: (*5 ~
*0) ° C Humidity: (*0 ~ *0)% RH
Storage conditions: Temperature: (**0 ~
**0) ° C
Protection class: IP*5: when waterproof
rubber ring between the controller and the control panel.
IP*2: When there is no waterproof rubber ring
between the controller and the control panel.
Dielectric strength: Object: Input /
Output / Power
Reference Standard: IEC*******2
Test method: AC1.5Kv/1min leakage current
3mA
Weight: 0.*0kg