Technical parameters of diesel generator sets:
Technical data | |
Genset Model | FF**0GF |
Prime Power | **0kw/**0kva |
Rated Voltage | **0/**0V |
Frequency | *0/*0Hz |
Power Factor | 0.8(lagging) |
The regulating rate of steady voltage | ≤±0.5% |
The regulating rate of instantaneous voltage | ≤**5%/ **0% |
The time of steady voltage | ≤1.5sec |
The waving rate of voltage | ≤1.0% |
The regulating rate of steady frequency | ≤3% |
The regulating rate of instantaneous frequency | ≤±*0% |
The time of steady frequency | 3sec |
Dimension (L×W×H) (mm) | ***0x***0x***0 |
Genset weight (kg) | ***0 |
Diesel Engine | |
Brand | Deutz |
Number of Cylinde | 4 |
Rotating Speed | ***0/***0RPM |
Cycle | Four stroke |
Type | waste gas turbine boost,direct spurting type |
Bore×Stroke(mm) | **2***0 |
Displacement(L) | 4.*6 |
Lubricating Capacity(L) | *3 |
Speed Governor | Electrical |
Cooling System | Water-cooled |
Speed Stability (%) | ≤5% |
Fuel Consumption at **0% Load | **5g/kw.h |
Starting Method | DC*4V Electrical starting |
Alternator | |
Brand | Stamford |
Number of Phase | 3 |
Connecting Type | Three Phase and Four Lines |
Number of Bearing | 1 |
Grading Protection | IP*2 |
Altitude | ≤***0m |
Exciter Type | Brushless (AVR automatic voltage regulating) |
Insulation Class | H degree |
The components of the genset | |
(1) deutz Diesel Engine; (2) Stamford Alternator; (3) Control Panel | |
Control Panel | |
The control panel is Quadruplication protection control panel, with the display of frequency table/water temperature/schedule/battery voltmeter. The genset with low oil pressure, high water temperature, over speed emergency, stop and other pre-protection. |
The following engine brands, alternator brands and Control panel for optional
Rated power | Engine | Alternator | Control panel |
*0kw~***0kw | Cummins |
Stamford Leroy somer Mecc alte ABB |
deepsea comAp Harsen Smartgen |
8kw~***0kw | Perkins | ||
*8kw~**4kw | Volvo | ||
*0kw~**0kw | Deutz | ||
**0kw****0kw | MTU | ||
**0kw***0kw | MAN | ||
**0kw****0kw | Mitsubishi | ||
*0kw***0kw | Doosan Daewoo | ||
2kw~***0kw | Chinese engines |
1. Control System:
1) Basic control system, the basic type control system is provided with a current meter, a volmeter,a frequency meter, an oil pressure guage, a water thermometer and indicator lights on the control cabinet and 4 additional protection fuctions
2) AST (Automatic Start Control System), Optional Automatic Start Type System is provided When there is an interruption in the commercial power supply (or there is a start signal in other generator sets), this generator set will, subject to time delay acknowledgement (***0 S adjustable), be automatically started (**8 times adjustable). In addition, it is provided with a basic protection function and digital or meter indication of voltage, current, frequency and rotation speed parameters.
3) Sync Parallel Control System, this control system can connect 2 or 3 or 4 gensets to make more larger power. such as: if you want ***0kw power, you can choose 2 sets **0kw gensets to work together
2. ATS (Automatic Transfer System)
The optional system is provided with a fully automatic transfer switch, a control electric apparatus and an indicator light on the control panel and is coordinated with an automatic type contral cabinet, thus serving the fuction of automatic changeover between the power supplied by the grid and the power generated by the genset
3. Open;Silent;Trailer type
1) Open Type