High Energy Arc (HEA) Igniter The
function of a burner is to ignite and burn the fuel by efficiently
and completely mixing it with combustion air in the
furnace. Prior to the invention of High Energy
Arc Igniter, a pilot burner smaller than the main burner
usually ignited by electric spark for a proven ignition energy
source required to light off the main oil burner. High
Energy Arc Ignitersare now being applied to all
new modern burners. These Igniters eliminate the use of pilot gas
igniter by directly igniting the oil with low voltage, high
amperage spark. A typical
High Energy Arc Igniter system consists of spark
rod assembly, spark tip, cable assembly, exciter box, retractor
assembly etc., High energy can
be provided with less weight, lighter wire and greater portability
by using a high voltage capacitor-discharge system. A large-value
capacitor stores energy during the arming sequence, releasing it in
a fraction of a second when it is switched on. To use the energy
efficiently, the igniter must be designed for high
voltage. We have developed
various igniters for all types of burners. Depending upon the
customer requirement, we can supply a suitable High Energy
Arc Igniter. Our HEA Igniters are very
efficient, light weight, compact design and needs less
space.
Exciter: Input voltage:
**0VAC/**0VAC Output Voltage: > ***0
VDC Stored energy: *2
joules Spark rate: 4
spark/sec Duty cycle: *5 sec ON/*0sec
off Dimensions (Approximate): Width***0
mm Height***0 mm Depth- **0 mm. Flexible
Cable: Length: **5 mm
max Operating Voltage: ***0 VDC
max Bend Radius: **0 mm
min Construction: PVC coated
conduit Spark
Rod: Length: ***0 mm Operating voltage: ***0
VDC Construction: SS tube/ SS flexible
hose Retractor
Assembly: Pneumatic power cylinder: **0 mm
stroke Operating pressure: *0 to **0
psi Solenoid valve: two position four
way solenoid valve Solenoid operating voltage: **0 VAC
/**0 VAC Mechanical Limit switch: 1 form C
for close and open positions Our HEA Igniters are First World Products at
Third World Price