看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
kvv 1.5 mm2 pvc insulated and sheathed 2/3/4/5/6/7/8/10 core control cable

kvv 1.5 mm2 pvc insulated and sheathed 2/3/4/5/6/7/8/10 core control cable

离岸价格

获取最新报价

0.05 ~ 5 / Meter ( Negotiable )

|

Minimum Order

位置:

-

最小订单价格:

最小订单:

200 Meter

包装细节:

as requests

交货时间:

within 10 days

供应能力:

100000 Meter per Week

付款方式:

T/T, L/C, Western Union, Money Gram, PayPal

现在联系
免费会员

联系人 Cathy

Xian, Shaanxi

现在联系

详情

kvv 1.5 mm2 2/3/4/5/6/7/8/*0 multi core pvc insulated and sheathed power control cable 
Product name:**0/**0V copper pvc cable 2 core 3 core 4 core 5 core 6 core 7 core 8 core *0 core *2 core *4 core *6 core *9 core *4 core *7 core *0 core *7core 0.*5mm2,1mm2 1.5mm2 2.5mm2 4mm2 6mm2 *0mm2 pvc insulated and sheathed control cables 
A. This product is suitable for the control monitoring circuit of AC rated voltage U0/U of **0/**0V and below and the connecting line of electrical instrument in protection circuit and power distribution device. It has good shielding effect and anti-interference effect.

B. Product standard:GB/T ********8
C. The type and specifications of cable are shown in the table below.

Insulation type

Type

Name

Core numbers

Nominal cross sectional area(mm2)

PVC

KVV

Control cable of copper conductor, PVC insulated and PVC sheathed

***1

0.***0

KVVR

The control flexible cable of Copper conductor, PVC insulated, and PVC sheath

XLPE

KYJV

Control cable of copper conductor, XLPE insulated and PVC sheathed

KYJVR

The control flexible cable of Copper conductor, XLPE insulated, and PVC sheath

D Running performance
a. The temperature should not be lower than 0 °C when the cable laying.
b. The long-term allowable operating temperature of PVC insulated cable conductors is *0 °C, and the maximum operating temperature of cable conductors is **0 °C when short-circuited (maximum duration does not exceed 5 seconds); the long-term allowable operating temperature of XLPE insulated cable conductors is *0 °C, short-circuit (The maximum duration does not exceed 5S) The maximum operating temperature of the cable conductor is **0 ° C;
c. The allowable bending radius of the cable: the cable without armor layer shall be not less than 6 times the outer diameter of the cable; the cable with armored or copper tape shielding structure shall be not less than *2 times the outer diameter of the cable; and the cable with shielded, it should be no less than 6 times the outer diameter of the cable.