看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell covid-19 igg/igm test kit

Sell covid-19 igg/igm test kit

离岸价格

获取最新报价

1.5 ~ 2 / Piece

|

Minimum Order

位置:

No. 38 Dongfang Road, Wenzhou, Zhejiang, China

最小订单价格:

最小订单:

10000 Piece

包装细节:

carton

交货时间:

15day

供应能力:

80000 Piece per Day

付款方式:

T/T, L/C

现在联系
免费会员

联系人 Mr. zhibin

38 Dongfang Road, Wenzhou, Zhejiang

现在联系

详情

MATERIALS Materials Provided
1)Foil pouches, with test cassettes and disposable droppers
2)Assay buffer
3)Instruction for use
Materials Required But Not Provided
1)Specimen collection container
2)Lancet
3)Centrifuge (for plasma only)
4)Timer DIRECTIONS FOR USE Allow the test, specimen, buffer and/or controls to reach room temperature (****0°C) prior to testing.
1. Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.
2. Place the cassette on a clean and level surface.
 ForSerum or Plasma   specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen to thefill line(approximately *0mL), and transfer the specimen to the specimen well (S), then add 2 drops of buffer(approximately *0mL), and start the timer.
· To use a pipette: To transfer*0mLof specimen to the specimen well(S), thenadd 2 drops of buffer(approximately *0mL), and start the timer
ForVenipuncture Whole Blood specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen about1 cm above the fill lineand transfer1 full drop(approx. *0μL) of specimen to the sample well(S). Then add2 drops of buffer(approximately *0mL) and start the timer.
· To use a pipette: To transfer 10 mL of whole blood to the specimen well(S), then add 2 drops of buffer(approximately *0mL), and start the timer
ForFingerstick Whole Blood specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen about1 cm above the fill lineand transfer1 full drop(approx. *0μL) of specimen to the sample well(S). Then add2 drops of buffer(approximately *0mL) and start the timer.

  • To use a capillary tube: Fill the capillary tube and transfer approximately *0mL of fingerstick whole blood specimen to the specimen well (S) of test cassette, then add 2 drops of buffer(approximately *0mL) and start the timer. See illustration below.
  • Wait for the colored line(s) to appear.Read results at *5 minutes.Do not interpret the result after *0 minutes.
Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.
 

Send a direct inquiry to this supplier

至:

Mr. zhibin < Wenzhou Astock Biotechnology Co., Ltd >

我想知道: