离岸价格
获取最新报价1 ~ 20 / Acre ( Negotiable )
|Minimum Order
位置:
-
最小订单价格:
最小订单:
50 Unit
包装细节:
Individual papar box, master carton
交货时间:
10-30 days
供应能力:
100000 Unit per Month
付款方式:
T/T
联系人 Donna
Zhuhai, Guangdong
Features | ||||||||||||||||
● Constant voltage output, 50/60Hz | ● Typical lifetime ≥ 50000 hours | |||||||||||||||
● Plastic case with terminal,Class I. | ● 100% full load bur-in test | |||||||||||||||
● Built-in EMI filter with tiny ripple,flicker-free | ● Protection: Short circuit/Over current/Over voltage/Over load | |||||||||||||||
● High performace and reliability | ●5 years warranty | |||||||||||||||
|
||||||||||||||||
Specifications | CE RoHS SELV | |||||||||||||||
Model# | Rated Power | Input Voltage | Output Voltage | Output Current | THD | Efficiency | PF | IP | Dimension | Weight | Warranty | |||||
NC-12012-LV | 12W | 200-240Vac | 12V | 1.00A | 14% | ≥83% | ≥0.6 | IP20 | 83*29*20mm | 70g | 5 years | |||||
NC-24012-LV | 24V | 0.50A | 15% | |||||||||||||
NC-36012-LV | 36V | 0.33A | 17% | |||||||||||||
NC-48012-LV | 48V | 0.25A | 18% | |||||||||||||
NC-12020-LV | 20W | 200-240Vac | 12V | 1.67A | 14% | ≥84% | ≥0.6 | IP20 | 94*36*17mm | 80g | 5 years | |||||
NC-24020-LV | 24V | 0.83A | 15% | |||||||||||||
NC-36020-LV | 36V | 0.56A | 17% | |||||||||||||
NC-48020-LV | 48V | 0.42A | 18% | |||||||||||||
NC-12030-LV | 30W | 200-240Vac | 12V | 2.50A | 15% | ≥85% | ≥0.6 | IP20 | 107*40*22mm | 110g | 5 years | |||||
NC-24030-LV | 24V | 1.25A | 16% | |||||||||||||
NC-36030-LV | 36V | 0.83A | 18% | |||||||||||||
NC-48030-LV | 48V | 0.63A | 19% | |||||||||||||
NC-12060-LV | 60W | 200-240Vac | 12V | 5.00A | 15% | ≥86% | ≥0.6 | IP20 | 132*44*28mm | 180g | 5 years | |||||
NC-24060-LV | 24V | 2.50A | 16% | |||||||||||||
NC-36060-LV | 36V | 1.67A | 18% | |||||||||||||
NC-48060-LV | 48V | 1.25A | 19% | |||||||||||||
NC-12080-LV | 80W | 200-240Vac | 12V | 6.67A | 15% | ≥87% | ≥0.6 | IP20 | 170*50*30mm | 250g | 5 years | |||||
NC-24080-LV | 24V | 3.33A | 16% | |||||||||||||
NC-36080-LV | 36V | 2.22A | 18% | |||||||||||||
NC-48080-LV | 48V | 1.67A | 19% | |||||||||||||
NC-12100-LV | 100W | 200-240Vac | 12V | 8.33A | 15% | ≥88% | ≥0.6 | IP20 | 190*63*30mm | 380g | 5 years | |||||
NC-24100-LV | 24V | 4.17A | 16% | |||||||||||||
NC-36100-LV | 36V | 2.78A | 17% | |||||||||||||
NC-48100-LV | 48V | 2.08A | 18% | |||||||||||||
Characteristics | Frequency | 50/60Hz | ||||||||||||||
Voltage tolerance | ±5% | |||||||||||||||
Load regulation | ±5% | |||||||||||||||
Leakage current((mA ) | < 0.5mA / 230VAC | |||||||||||||||
Ripple&noise | < 650mVP-P | |||||||||||||||
hold-up/start-up time time | 100ms, 30ms,20ms/ 230VAC | |||||||||||||||
Leakage current((mA ) | < 0.5mA / 230VAC | |||||||||||||||
Protection | Over current | above 108%-116%,power limiting, recovers automatically after fault removed | ||||||||||||||
Over voltage | switch off, recovers automatically after fault removed | |||||||||||||||
Short circuit | hiccup mode,recovers automatically after fault removed | |||||||||||||||
Environment | Operating Temperature | -25℃~~+45℃ | ||||||||||||||
Storage Temperature | -30℃~~+80℃ | |||||||||||||||
Humidity | 20~~95% | |||||||||||||||
Security | LVD | 2014/35/EU,EN61347-1:2015,EN61347-2-13:2014 | ||||||||||||||
EMC | 2014/30/EU,EN55015:2013+A1:2015, EN61547:2009,EN61000-3-2,EN61000-3-3:2013 | |||||||||||||||
Voltage Insulation/Isolation Resistance | I/P-O/P:3.75KVAC,I/P-O/P:>100M Ohms/500VDC/28℃/65% RH | |||||||||||||||
Classification of Installation and Use | Class I | |||||||||||||||
Note | ◊ All parameters NOT specially mentioned are measured at 240VAC input, max rated load and 25℃ of ambient temperature | |||||||||||||||
◊ Ripple & Noise are measured at 20MHz of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1uF & 47 uF parallel capacitor. | ||||||||||||||||
◊ The driver is considered as a component to be operated in combination with equipment,since performance will be affected by the complete installation. | ||||||||||||||||
◊ Good heat dissipation will prolong the working life of the driver.Please ensure good ventilation. | ||||||||||||||||
◊ Please check if the output voltage of any LED lights used comply with the working voltage of the product. | ||||||||||||||||
◊ Be ware of high power pressure may caused by short circut when installing metal casing products. | ||||||||||||||||
◊ Please ensure all wires connections and polarities are correct before appling power to avoid any damages to LED Lights. | ||||||||||||||||
◊ The product shall be installed and serviced by a qualified person. | ||||||||||||||||
◊ Please contact supplier if a fault occurs. |