Dilution Gas Sampling Probe series

Dilution Gas Sampling Probe series

离岸价格

获取最新报价

5000 ~ 5100 / Set

|

Minimum Order

位置:

-

最小订单价格:

最小订单:

1 Set

包装细节:

STANDARD EXPORT PACKAGE

交货时间:

25 DAYS

供应能力:

1000 Set per Year

付款方式:

T/T, L/C, D/A, D/P, Western Union

现在联系
免费会员

联系人 Ms. Wendy

East Jinyang road, Suzhou, Jiangsu

现在联系

详情

Dilution Gas Sampling Probe series     Dilution CEMS uses atmospheric grade PPb analyzer. Moisture and escaping NH3 may cause interface even damage to the NOX analyzer & CH4 kicker tube of SO2 analyzer. This probe uses unique external large proportion dilution sampling technology. It overcomes the loss caused by condensate water to the measured components in the process of sample gas pretreatment. Unique NH3 removal technology can avoid high concentration of escaping NH3 diluted into the analyzer, thus will protect analyzer from the crystallization.
 
Features
More stable dilution ratio,better consistencyReduce the water content in the sample gas, co-   mpletely eliminate the measurement influence of   condensed waterAfter remove dust & NH3, sample gas complete-   ly meets the requirements of the analyzerNo need heating lineSample gas transmission fast, less maintenance & consumablesDouble filtration( sampling probe cavity and sonic hole ), filtration level    0.1µm, effectively prevent sonic hole cloggingBackblow function, suitable for high dust, high pollution conditionsEscape NH3 removal rate is above *9%Standard dilution ratio: 1:**0 (other ratios are optional)
 
Principle
Step 1. The original flue gas enters the high temperature chamber after            passing the rod, the primary dust filtration begins in the chamber. Step 2. Filtered flue gas enters the NH3 remover,  the escaping NH3 is fil-            tered out to ensure that the sonic hole will not be blocked. Step 3  The flue gas enters the sonic hole. After being mixed with zero gas,            it enters the sampling pipeline under the power of jet pump. 
        Under this probe, there is no cold points, no SO2 loss in whole process.EscapingNH3 is completely removed. Thus it can ensure accurate and stable operation in theanalysis system. 


 

Model No. PW-SP-D series
Dilution air flow rate 6.**7.5 LPM,*0 Psig minimun
Diluted air purity **0℃ <1ppb CO,CO2,NOx, SO2
Vacuum port **5" Hg
Sonic orifice Duran glass
Absolute pressure of flue gas range  **0kpa~*0kpa
Backblow frequency outer control
Backflow time outer control
Fast recycle ejector choose according to the specific situation
Pressure for compressed air 0.4~0.7Mpa
Heat power **0W
Preheating time 2H
Control thermocouple Mechanical temperature controller

Send a direct inquiry to this supplier