看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Gold Atomic Absorption Spectrophotometer
Next

Gold Atomic Absorption Spectrophotometer

离岸价格

获取最新报价

0 ~ 5 USD ( Negotiable )

|

1 Set Minimum Order

国家:

China

型号:

GD-320N

离岸价格:

0 ~ 5 USD ( Negotiable ) 获取最新报价

位置:

China

最小订单价格:

-

最小订单:

1 Set

包装细节:

wooden cases

交货时间:

within 10 days

供应能力:

100 Set per Month

付款方式:

T/T, Western Union

產品組 :

现在联系
免费会员

联系人 Tina

9F/10, Jintai Building, Nanping, Chongqing, Chongqing, Chongqing

现在联系

详情

Characteristics A

  •  Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
  •  Good basic line stability: Double-beam system of optimized design can automatically compensate the light 

s ource drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

  •  High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
  •  Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.   
  •  Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
  •  Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
  •  Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame .
  •  Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

 

Characteristics B

  •  Light-source system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current
  •  Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: **0nm
  •  Flame atomization system: Inter-changeable titanium alloy burner of *0cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.
  •  Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

 

Technical Specifications

  •  Working spectral range: ******0nm
  •  Wavelength accuracy: ≤ ±0.5nm
  •  Wavelength repeatability: ≤ 0.3nm (single direction)
  •  Spectrum bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
  •  Resolution: <*0%
  •  Base line stability: ±0.**4Abs/*0min
  •  Characteristic concentration of copper: ≤ 0.*4mg/ml/1%
  •  Detection limit of copper: ≤0.**8mg/ml
  •  Background calibration ability: Greater than *0 times.
  •  Standby Interface: RS **2 
  •  Instrument power supply: **0V, 3A, *0Hz

 

Accessory

Main accessories supplied with the instrument: Several decades of accessories including air compressor, one piece of Cu hollow cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.

 

Optional accessories:

GA***2 HGA graphite furnace system: Used to conduct trace and ultra-trace analysis with an absolute sensitivity of **********2 gram.

5cm long-life titanium burner: The necessary accessory for nitrous oxide-acetylene flame analysis.

Hydride generator (Totally automatic): Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In, Tl, Cd and Zn lower than ppb level with cold atomic mercury measurement method.

Hollow cathode lamp: All specifications are available.

Graphite tube: All specifications are available.

Software with I/O port

Printer


 

国家: China
型号: GD-320N
离岸价格: 0 ~ 5 ( Negotiable ) 获取最新报价
位置: China
最小订单价格: -
最小订单: 1 Set
包装细节: wooden cases
交货时间: within 10 days
供应能力: 100 Set per Month
付款方式: T/T, Western Union
產品組 : Testers

Send a direct inquiry to this supplier

至:

Tina < Chongqing Gold M&E Equipment Co., Ltd. >

我想知道: