Parameter | Function | Set range | Default |
E1 | Lower set point limit range | -40℉ -45℃~Set temp. |
-31℉ -35℃ |
E2 | Higher set point limit range | 120℉ 45℃~Set temp. |
68℉ 20℃ |
E3 | Temp. hysteresis | 1~18 ℉ 1~10℃ |
7℉ 4℃ |
E4 | Comp. Start delay time | 0~10min | 2min |
E5 | Offset on room temp. | -5~5 ℉/℃ | 0 |
E6 | Offset on evap. Temp. | -5~5 ℉/℃ | 0 |
F0 | Defrost type | 0=Electric
heat 1=Hot gas |
0 |
F1 | Max. Defrost duration | 1~60 min | 20min |
F2 | Defrost interval time | 0~24hr | 6hr |
F3 | Defrost termination temp. | 32~68 ℉ 0~20℃ |
46℉ 8℃ |
F4 | Display during defrost | 0=Normal display 1 = Last value before defrost |
0 |
F5 | Fan control | 0=Parallel with
comp. 1 = Continuous running (except when defrost) |
0 |
C1 | Temperature unit | 0=Celsius 1=Fahrenheit |
0 |
C2 | High temperature alarm | -40~0℃/℉(relative to set temp. Set value) |
20 |
C3 | Low temperature alarm | -40~0℃/℉(relative to set temp. Set value) |
-20 |
C4 | Alarm delay time | 1~90 Min | 60Min |