联系人 Jack
Shanghai, Shanghai
~
The limit control of sulfur content in petrochemical products,
especially in oil products (such as gasoline, diesel oil,
lubricating oil, etc.) has become the main focus in environmental
protection. According to the latest China Environmental
Protection Agency regulations in petrochemical industry,
automotive gasoline total sulfur index dropped from ***0pmm to
**0ppm, the current national standard Ⅳ sulfur content index has
dropped to *0ppm. Ordinary diesel index drops from ***0ppm to the
current **0ppm. In the meantime, the China Maritime Safety
Administration has stipulated that the sulfur content of the fuel
used by vessels in the emission control zone shall not exceed
0.5% m/m (***0ppm).
Performance Advantage
It is a high performance, portable XRF analyzer that provides the energy industry with the perfect sulfur elemental analysis method for analyzing elemental content in oils such as lubricants, diesel fuels, jet fuels, kerosene, other distillates, volatile oils, residual oils, hydraulic oils, crude oils, unleaded petrol, alcoholic gasoline, biodiesel. Also, it can check the existence of elements content, wear elements, pollutants and sulfur content in other similar petroleum products. It can be used in any place, providing safe, highquality sulfur content analyzing condition for liquid, solid or gas samples.
Equipped with a confined X-ray sample cabin
Highly flexible analysis software
No sample preparation, easy to collect and analyze samples
Low maintenance requirements (no heating components, no quartz tube, no column)
Users can customize the measuring time to achieve continuous monitoring
No need for any sample changeover, gas consumption, or high-temperature processes
Analysis of elements and patterns
Oil Portable Analyzer elemental detection limit
LOD of Sulfur
Element
3 sigama (ppm)
S (Sulfur)
0.9
Application range
Application Areas
Oil Portable Analyzer is used for the analysis of fuels, oils, additives and other fluids in the petrochemical, heavy traffic, power generation, aerospace, crude oil exploration, marine and other industries.
Specific applications are as follows:
Sulfur content analysis of marine fuels: Monitoring of sulfur content in the sulfur dioxide emission control area (SECA). Special fuel quality regulations emissions control areas exist in SOx emission control area (SOx ECA or SECA), including ports and coastlines.
Petroleum refining industry: Determining total sulfur in fuels and crude oil, or tracing impurities metals in refinery catalysts.
Refinery: Used for hydrofining units and blending systems.
Oil pipeline: Used for oil interface judgment and tank contamination judgment.
Wear elemental analysis: Accurate detection of additives containing Al, Si, P, S, Ca and Zn in various engine oils, engine oils, fuels and system oils. According to the concentration of different elements, determine the wear of metal machinery and the necessity for oil replacement.
Additive Analysis: Analyzing high-quality lubricants (mixed based on a special formulation of organic, metallic additives) for precision equipment at extreme temperatures and loads.
Hydrocarbon analysis: Measuring calcium, sulfur, magnesium, aluminum, phosphorus, silicon, chlorine, etc. in a certain concentration of hydrocarbons and aqueous solutions.
Technical parameters and specifications
Instrument Dimensions
**0(L)***0(W)***8(H)mm
Sample holder Dimensions
**0(L)***0(W)**0(H)mm
Weight
4.1KG
Excitation source
*0KV/**0μA maximum pipe pressure pipe flow 4W
Detector
SDD
Display system
Based on i.mx6 Quad quad-core Cortex-A9 processor
Dedicated analytical grade operating system, *2GB system
memory
Power Supply System
Intelligent battery management through MSBUS bus, real-time
monitoring of the residual capacity of
battery and backup battery. The battery complies with air transport regulations of dangerous goods.
A single battery can last 8 hours.
Resolution
Optimal<**6eV
Data transmission
USB, Bluetooth
Operating environment temperature
**0℃~*0℃
Operating environment humidity
*0%~*0% relative humidity, non-condensing
Display
5.7″ retractable color touch screen display
Test time
User-defined
Safety protection
Built-in radiation protection device (automatically cut off)
Safety interlock, can open the instrument only in power on condition, (seal performance)
Radiation indicator
Camera
Built-in 5 megapixel high-definition camera
Relevant standards
OIL Portable XRF Analyzer meets the following testing standards
GB/T*********8 Determination of sulfur in Chinese petroleum and
petroleum products
GB/T *********8 Determination of Sulfur in Chinese Crude Oil
GB/T *******7 Determination of sulfur content in Chinese petroleum products
GB/T *********5 Marine fuel oil
SH/T ********2 Determination of total sulfur in light petroleum products
SH/T ********6 Determination of barium, calcium, phosphorus, sulfur and zinc in lubricating oils and additives
ISO ********3 Determination of sulfur content of International petroleum products
ISO *********4 Determination of sulfur content of International petroleum products, motor fuel
ISO *********0 Determination of sulfur content of international gasoline fuels
ISO *********4 Determination of sulfur content of International petroleum products, motor fuel
USA ASTM D***4 Test Methods for Sulfur in U.S. Petroleum and Petroleum Products
USA ASTM D***0 Standard Test Method for Sulfur in U.S. Petroleum and Petrochemical Products
USA ASTM D********7 Test Method for Sulfur in US Gasoline and Diesel
USA ASTM D********9 Test Method for Total Sulfur in Engine Fuels and Engine Oil in the United States
ASTM D********9 Standard Test Method for Phosphorus, Sulfur, Calcium and Zinc in U.S. Lubricants
国家: | China |
型号: | - |
离岸价格: | 获取最新报价 |
位置: | - |
最小订单价格: | - |
最小订单: | - |
包装细节: | - |
交货时间: | - |
供应能力: | - |
付款方式: | - |
產品組 : | - |