看起來你不是TradeKey.com的會員。 立即註冊,與全球超過7百萬的進口商和出口商建立聯繫。 点击注册--免费! |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Surface Area and Pore Size Distribution Analyzer
Next

Surface Area and Pore Size Distribution Analyzer

离岸价格

获取最新报价

( Negotiable )

|

1 Set Minimum Order

国家:

China

型号:

JW-BK200B

离岸价格:

( Negotiable ) 获取最新报价

位置:

Beijng, China

最小订单价格:

-

最小订单:

1 Set

包装细节:

-

交货时间:

30 days

供应能力:

1000 Set per Year

付款方式:

Other, PayPal, D/P, L/C, T/T

现在联系
免费会员

联系人 Ms. Wendy

A Block,No.23,South Binhe Road, Beijing, Beijing

现在联系

产品规格

  • Brand Name: JW-BK200B

详情

Test principle: the static volumetric method, gas adsorption;
Analysis Models: BET, Langmuir, BJH, t-plot, DR, αs-plot, MP, HK, SF, and NLDFT;
Measuring range: surface area ≥ 0.**5M2/g, no upper limit; mesoporous and macroporous 2 _ **0nm; micropore size 0.*5nm _ 2nm; pore volume 0.***1 cm3/g, no upper limit.
Sorption gas:N2 (high purity); Ar, Kr, CO2, CH4, etc. available
Analysis Stations: 2 ports. One analysis station can test the micropore and the other can test the mesorpore.
Sample Type: powders, granules, fibers, flakes and other materials
Pressure Sensor: ***0torr (**3kpa), *0torr (1.*3kpa); 1torr (0.**3kpa) or 0.1torr (0.***3kpa); accuracy≤± 0.*5%P.S
P0 tube: there is a separate P0 tube in every analysis port, two in all, controlled by a separate pressure sensor, completely separates from the analysis port, real-time detecting the nitrogen saturation vapor pressure, and participating in the theoretical calculation; also the atmospheric method to determinate the P0 accurately;
Cold trap tube: sample degassing system has a special cold trap device that can effectively remove the water, hazardous substances and other impurities, degassed from the special sample, and it can avoid the contamination of the vacuum system;
Degassing system: Parity, ectopic vacuum degassing pretreatment systems are controlled by separate pressure sensors. Two samples can be analyzed simultaneously, also two samples can be degassed in degassing ports; two independent sample degassing stations are separate from the sample analysis ports. The degassing system has two independent heating packages, two independent temperature control systems, which can be programmed by temperature control; you can choose another four external vacuum degassing pretreatment system;
Degassing temperature: room temperature ***0, accuracy ± 1;
Nitrogen Partial Pressure: P/Po 1×***8 _ 0.**8, the minimum resolvable relative pressure 5 × ***7
Ultimate vacuum:≤ *0P*6 Pa7.5×***9 torr, mechanical pump and turbo molecular pump.
Pressure Accuracy: ≤ ± 0.*5% (P.S)
 

国家: China
型号: JW-BK200B
离岸价格: ( Negotiable ) 获取最新报价
位置: Beijng, China
最小订单价格: -
最小订单: 1 Set
包装细节: -
交货时间: 30 days
供应能力: 1000 Set per Year
付款方式: Other, PayPal, D/P, L/C, T/T
產品組 : Static Volumetric Method

Send a direct inquiry to this supplier

至:

Ms. Wendy < Beijing JWGB Sci & Tech. Co., Ltd. >

我想知道: