SXVLF 30/40/50/60/70/80/90KV VLF AC Hipot Test Set For Power Cable
Prev
SXVLF 30/40/50/60/70/80/90KV VLF AC Hipot Test Set For Power Cable
Next

SXVLF 30/40/50/60/70/80/90KV VLF AC Hipot Test Set For Power Cable

离岸价格

获取最新报价

( Negotiable )

|

1 Set Minimum Order

国家:

China

型号:

SXVLF Series

离岸价格:

( Negotiable ) 获取最新报价

位置:

-

最小订单价格:

-

最小订单:

1 Set

包装细节:

Plywood Cases

交货时间:

15 working days

供应能力:

20 Set per Year

付款方式:

T/T, L/C, Western Union

现在联系
免费会员

联系人 YING

Wuhan, Hubei

现在联系

产品规格

  • Test Voltage Range:30kv/40kv/50kv/60kv/70kv/80kv/90kv

详情

General information:

VLF Test Sets from *0kV - *0kV with Sine Wave Output

VLF means 'Very Low Frequency' is used in AC hipot test for power cables, transformers, switchgear and other electrical apparatus.

A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than *0/*0Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than *0Hz, it takes **0 times less current and power to apply an AC voltage to a capacitive load, like a long cable.

 

Features:

√  Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.

√   Portable, easy to move.

√   Large LCD can display waveform clearly, and test report can be printed by built-in printer.

√   The data of current, voltage, and waveform can be sampled at HV side.

√   Over voltage protection: When the output is beyond the limitation, the control unit will shut itself down within *0ms.

√   Over current protection: high & low voltage double protection, the precision value of power off protection can be setting at HV side. When the current of LV side is exceeded rated, the control unit will shut itself down within *0ms.

√   HV output protection resistor is built in the booster, not need to connect outside resistor.

√   Adapting high & low voltage closed loop negative feedback control circuit, there is no capacitive rise effect during the output.

Specifications:

Model Output Voltage/Current
(Peak)
Load Capacity Fuse Control Unit Booster
Net Dim.
(cm)
Net Wt
(kg)
Net Dim.
(cm)
Net Wt
(kg)
SXVLF**0/1.1 *0KV/*9mA 0.1Hz ≤ 1.1uF 8A *8×*7×*2 4 *3×*8×*4 *5
0.*5Hz ≤ 2.2uF
0.*2Hz ≤ 5.5uF
SXVLF**0/1.1 *0KV/*9mA 0.1Hz ≤ 1.1uF  
8A
 
*8×*7×*2 4 *5×*0×*6 *5
0.*5Hz ≤ 2.2uF
0.*2Hz ≤ 5.5uF
SXVLF**0/1.1 *0KV/*9mA 0.1Hz ≤ 1.1uF  
*0A
 
*8×*7×*2 4 *7×*4×*9 *5
0.*5Hz ≤ 2.2uF
0.*2Hz ≤ 5.5uF
SXVLF**0/0.5 *0KV/*9mA 0.1Hz ≤ 0.5uF  
*0A
 
*8×*7×*2 4 *3×*8×*4
*3×*8×*4
*5**5
0.*5Hz ≤ 1.0uF
0.*2Hz ≤ 2.5uF
SXVLF**0/0.5 *0KV/*9mA 0.1 Hz, ≤0.5µF  

国家: China
型号: SXVLF Series
离岸价格: ( Negotiable ) 获取最新报价
位置: -
最小订单价格: -
最小订单: 1 Set
包装细节: Plywood Cases
交货时间: 15 working days
供应能力: 20 Set per Year
付款方式: T/T, L/C, Western Union
產品組 : HV HIOPOT TEST SET