Test Setting:Programmable for
single-parameter,multi-parameter,combined parameter,batch test
Test Range:Clinical
Biochemistry,Turbidimetry,ISE,Protein,Drug abuse
Parameter Setting:Completely oper for editing test
parameters and calculation parameters
Sample System:
Sample Tray:*4 sample positions for primary tubes,test
tubes and various sample cups
Whole sample tray can be removed and replaced
Any position can be aligned as the emergency test position
Sample Volume:3µl~ *0µl,programmed by 0.1µl step
Sample Handling:Dilute and retest automatically when
samples concentration beyong limitation
Sample probe:Liquid level detection and
collision protection
Probe cleaning:Automatic washing for both inside
and outside,carry over ?0.1%
Syringe:High performance syringe,durable and
maintenance free
Optional item:Bar code reader
Reagent System:
Reagent tray:*4 positions for Single & Dual
reagents,reagent positions can be aligned freely
Refrigeration:Refrigerated reagent
compartment,*4 hours non-stop cooling with Peltier element
maintaining temperature 4~*5?
Reagent bottle volume:*5ml and *0ml,Slope bottom
design
Reagent volume:**0µl ~**0µl ,programmed by 0.1µl
step
Reagent probe:Automatic liquid level detection
function and collision protection
Reagent pre-heating function,inventory checking
Real time monitoring of reagent residual volume and auto alarm.
Probe cleaning: Automatic washing for both
inside and outside,carry over 0.1%
Reaction System
Reaction tray:*8 reaction cuvettes with 6mm
optical path,good UV penetrability,low consumable,low cost
Reaction technology:Back-Dividing-Light
Technology
Reaction volume:**0µl ~**0µl
Temperature:*7?,with+ 0.1? flutuation
Mixing system:Independent mixer
Cleaning:Automatic cuvettes cleaning and
complete drainge to reduce carry over
Water consumption:5L/hour
Liquid detection:Detergent,distilled water,waste
liquid automatic detection and alarm
Optical System:
Light source:Halogen lamp 6V/*0W,life span≥
***0hours
Wavelength:**0nm,**5nm,**0nm,**2nm,**5nm,**6nm,**8nm,**0nm,**0nm,**0nm
Wavelength accuracy:±2nm
Detector: Photoelectron Diode Array
Absorbance range:0.**0Abs~3.**0Abs
Calibration & Quality Control
Calibration mode:Linear (one-point,two-point and
multi-point),Logit-Log4P,Logit-Log5P,Spline,Exponential,Polynomial,Parabola
QC rules:Westgard Multi-rule
QC mode:Intra day & Inter day QC
Operating System:
Computer:Windows ***0 System or above
Data management:Large capacity for results and
reaction curves to be displayed,saved and printed
Report:Edit and print complete reports,format
editable,support network printing
Port:RS***2
Working Conditions:
Power:**0V±*2V,*0/*0Hz±1Hz
Power consumption:≤**0VA
Environmental temperature:*5?~*0?
Humidity: ≤*5%
Dimension:**0(L) x **0(W) x***8(H)mm
Weight:≥*5Kgs