Technical Data | ||||
Properties | Unit | Test Method | Min | Max |
Specific Gravity @25°C | gr./cm3 | ASTM D70 | 1.01 | 1.05 |
Penetration @ 25°C, 100g, 5s | dmm. | ASTM D5 | 80 | 100 |
Softening Point | °C | ASTM D36 | 45 | 52 |
Ductility @ 25°C | cm | ASTM D113 | 100 | --- |
Loss on heating | % | ASTM D6 | --- | 0.5 |
Drop in Penetration after heating | % | ASTM D5 & D6 | --- | 20 |
Flash Point | °C | ASTM D92 | 230 | --- |
Solubility in Trichloroethylene | % | ASTM D2042 | 99 | --- |
Spot Test | --- | AASHTO T102 | NEGATIVE | |
Test Result after TFOT (5 Hours @ 163°C) | ||||
Loss on Heating | %(wt.) | EN 12607-2 | --- | 0.2 |
Retained Penetration | % | EN 12607-2 | 52 | --- |
Ductility @ 25°C | cm | ASTM D113 | 100 | --- |