Application:
IIJ series fully automatic oil tester is designed as per the requirement of IEC**6 Testing Method of Insulation Oil Medium Strength, which via proper programming, has got functions of auto boosting, step down, stirring, display and print out. After breakdown of oil medium, HV break off will operate within *0 seconds to enable an auto isolation of control system partly; this effectively safeguards the personnel security and equipment safety. The tester is suited for testing of the strength of insulating oil medium, as well as for testing of withstands voltage of transformer oil.
 
Features :
1) Fully automatic, control by microcomputer, utilization of new I/O terminal.
2) Numbers of times of testing and idling time of stirring are set via digital setting.
3) Test results displayed and printed out automatically.
4) Strong capability of anti-interference.
5) High accuracy of testing and high capacity of anti-jamming.
6) Easy to operate, small size, light weight which operated in the open air very conveniently and convenient for maintenance
7) Can store *9 groups oil testing data which is convenient to reading and print. The testing data can keep **0 years under the condition of power off.
8) System time can go on running under power off.(the system time just for reference can not be the standard of timing)
 
Technology and parameter data
1. Power supply: AC**0V *0%, *0 HZ
2. Voltage output: *0 KV, *0KV, **0KV
3. Capacity: 1.6KVA, 2.0KVA
4. Pressure increase rate : About 2 KVA/S
5. Pressure testing speed: 3%
6. Break down sensitivity : <2KV
7. Wave form distortion :≤3%
8. Time of break down: ≤*0ms
9.  Operational environment: Temperature:0°C**0°C, Humidity: the most relative humidity*5%
*0. Storage environment : Temperature:**0°C**0°C, Humidity: the most relative humidity*5%.
*1. Operational height: <**0m (can be specially designed if the height is over ***0m)
*2. Test cell: Glass, volume **0 to **0 ml, with protective cover and stirrer.
*3. Electrodes: Stainless steel spherical *6 mm diameter/hemispherical *5 mm radius,   2.5 mm gap as per IEC***6.
*4. Nitial stand time of oil sample: **0 seconds
Intermediate stand time of oil sample: *0 seconds
String time of oil sample:  *0 seconds
Number of consecutive test: 6
*5.Weight: *8kg