● Low DC-side voltage, only **0 V required, that has effective
improved the life of both IGBT and DC capacitors, is the national
initiative (patent number: ***********0.2).
● Easy to install on site, especially for renovation
projects, no current transformer needs to be added, instead of the
original and the PSPP owns can implement the monitoring and control
of harmonics.
● **-inch high-definition touch screen, friendly man-machine
interface, providing complete on-site information, historical
information, and power quality comparison before and after
filtering. Not only harmonic-filtering function, but also
harmonic-detecting function that PSPP gives you, by such a screen
you may conventionally know about harmonics in your grid and the
quality of the electrical energy.
● Modular design, pre-installation, ease of maintenance.
● High harmonic filtering efficiency, effectively filter out
the 2nd - *0th harmonics, also to the order-given.
● Fully digital-control DSP, with high-speed detection and
operation, responds quickly to the dynamic changes of load, a full
response time of less than 5 ms, ensures accurate and efficient
harmonic detection and compensation control, and gives a full
inhibition of voltage fluctuations and flicker.
● Can dynamically compensate for single-phase or three-phrase
system harmonics, and the compensation effect meets the national
standard GB/T*******3 Quality of Electric Energy Supply – Harmonics
in Public Supply Network.
● No overload phenomenon, always run reliably even when
encountering big harmonic current.
● Its filtering effect is free from systemic impedance
changes, without syntony and harmonic amplification.
● Filtering, or filtering and / or reactive power
compensation, you chose.
● Easy to operate and maintain, and multiple parallel
operation can also be done.
● Centralized compensation or decentralized compensation is
based on your power distribution structure.
● Standard communication interface(s).
● Complete protection functions: overload, over-temperature,
over-voltage, over-current, under-voltage, fault self-diagnosis,
etc.
● Effectively eliminate the zero-sequence harmonic and its
generated neutral current (SNTA***8/4L series).
The functional principle is: in real time detect a load current
waveform to find its harmonic current, then control IGBT triggering
to inject direction-opposite equivalent current into power supply
system, to achieve to filter off (offset) the harmonic, dynamically
compensate. systemic reactive power and suppress voltage
fluctuations and flicker, suppress resonance, and improve power
factor and other functions, so as to improve the security of the
power supply system and achieve the purpose of energy saving.
PSPP internal control principle is: After circuit breaker closing,
PSPP firstly charge the DC bus capacitor by a pre-charge resistor,
to prevent instant impact on the capacitor after power on. 8
seconds later, when the bus voltage Vdc reaching the rating, the
master contactor is closed.
DC capacitor is an energy storage component, externally energizing
to output compensation current via IGBT inverter and internal
reactor, also internally energizing as a working power supply to
internal detection and control panels through power exchange
board.
SNTA***8 PSPP series through external CT collect current signal and
send to a harmonic detection module, to separate from fundamental
wave; then send the harmonic to a detection module to compare such
harmonic with the compensation current that PSPP outputs, the
difference as a real-time compensation signal to be output to the
drive circuit. Based on such signal, PSPP injects a compensation
current into the grid to filter harmonic out.